TDA523x
Functional Description
Notes to State Diagram Run Mode Slave:
1.) Wait: Waiting until start up sequencer has completed the power up procedure.
2.) Init: The Receiver will be initialized and the FIFO will be initialized when the SFR
control bit INITFIFO is set. Read out the Modulation Type Configuration (ASK or
FSK), which is defined in the SFR control bits AMT/BMT and set the device to the
configured mode. Set the channel to the correct value, which is defined in the
ARFPLL1/BRFPLL1 register.
3.) FIFO locked: When the signal fifolk is set, the chip enters this state and remains
there until the signal fifolk is reset. In this state, no further data reception is possible
and therefore, no SYNC or FSYNC will be generated, even if a data-packet is present
in the received data stream. (More information on the FIFO behavior can be found in
chapter Chapter 2.4.15 Data FIFO).
4.) Wait: Wait until symbol synchronization is complete. A loss of symbol
synchronization always leads into this state, whatever the current state is. This state
is left only, if symbol-synchronization can be established on the received data stream.
(More information on the synchronization behavior can be found in Chapter 2.4.13
Frame Synchronization).
5. Wait: Wait until a start of a data packet (frame) is detected. All bits received from
FSYNC until the detection of EOM will be transferred to the FIFO.
6.) INIT FIFO: The FIFO will be initialized, if the SFR control bit FSINITFIFO is set
7.) Check MID Setup: Check the configuration of the Message ID Unit. Depending on
the SFR control bit MIDSEN a Message ID scanning is started or not. If no Message
ID scanning is selected, the next state is the state EOM check. Otherwise the
Message ID scanning unit is activated to search for a valid Message ID.
8.) Init MID Scanning Unit: Initialize the Message ID scanning unit.
9.) Wait: Wait until the Message ID scanning unit has finished the search for a valid
message ID. All incoming data is stored in the FIFO.
10.)Checking ID Scanning Result: The result of a search for a Message ID is checked.
If no valid MessageID was found, a search for a new frame is started. Be aware that
all received bits after FSYNC were stored in the FIFO, even if no Message ID was
found. After a successful search for a Message ID , the next state will be EOM check.
11.)EOM Check: Incoming data bits are transferred to the FIFO until an EOM is
detected. The criteria for EOM are defined in the AEOMC/BEOMC register. If the
SFR control bit FIFOLK is set, the signal fifolk will be asserted at EOM. Depending
on the state of fifolk, the next chip state will be FIFO locked or Wait for Symbol
Synchronization.
Data Sheet
37
Version 4.0, 2007-06-01
 