datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

P0080EAL View Datasheet(PDF) - Littelfuse, Inc

Part Name
Description
View to exact match
P0080EAL
Littelfuse
Littelfuse, Inc Littelfuse
P0080EAL Datasheet PDF : 3 Pages
1 2 3
SIDACtor® Device
RoHS
TO-92 SIDACtor solid state protection devices protect telecommunications equipment such
as modems, line cards, and CPE (telephones, answering machines, and fax machines).
SIDACtor devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
.
Electrical Parameters
Part
Number *
P0080E_L
P0300E_L
P0640E_L
P0720E_L
P0900E_L
P1100E_L
P1300E_L
P1500E_L
P1800E_L
P2300E_L
P2600E_L
P3100E_L
P3500E_L
VDRM
Volts
6
25
58
65
75
90
120
140
170
190
220
275
320
VS
Volts
25
40
77
88
98
130
160
180
220
260
300
350
400
VT
Volts
4
4
4
4
4
4
4
4
4
4
4
4
4
IDRM
µAmps
5
5
5
5
5
5
5
5
5
5
5
5
5
IS
mAmps
800
800
800
800
800
800
800
800
800
800
800
800
800
IT
Amps
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
IH
mAmps
50
50
150
150
150
150
150
150
150
150
150
150
150
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For individual “EA”, “EB”, and “EC” surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
Surge Ratings in Amps
IPP
0.2x310 * 2x10 * 8x20 * 10x160 * 10x560 * 5x320 * 10x360 * 10x1000 * 5x310 * ITSM
0.5x700 ** 2x10 ** 1.2x50 ** 10x160 ** 10x560 ** 9x720 ** 10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz di/dt
Amps Amps Amps
Amps
Amps Amps Amps
Amps
Amps Amps Amps/µs
A
20
150
150
90
50
75
75
45
75
20
500
B
25
250
250
150
100
100
125
80
100
30
500
C
50
500
400
200
150
200
175
100
200
30
500
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse
3 - 19
www.littelfuse.com
 

Share Link: 