datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

74LVTH125BQ View Datasheet(PDF) - Philips Electronics

Part Name
Description
View to exact match
74LVTH125BQ
Philips
Philips Electronics Philips
74LVTH125BQ Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Philips Semiconductors
74LVT125; 74LVTH125
3.3 V quad buffer; 3-state
Table 7. Static characteristics …continued
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Typ
ICC
additional quiescent supply per input pin; VCC = 3 V to 3.6 V; [6] -
0.1
current
one input at VCC 0.6 V and
other inputs at VCC or GND
Ci
input capacitance
VI = 0 V or 3.0 V
-
4
Co
output capacitance
outputs disabled;
VO = 0 V or 3.0 V
-
8
Max
Unit
0.2
mA
-
pF
-
pF
[1] Typical values are measured at VCC = 3.3 V and Tamb = 25 °C.
[2] Unused pins at VCC or GND.
[3] This is the bus hold overdrive current required to force the input to the opposite logic state.
[4] This parameter is valid for any VCC between 0 V and 1.2 V with a transition time of up to 10 ms. From VCC = 1.2 V to VCC = 3.0 V to
3.6 V a transition time of 100 µs is permitted. This parameter is valid for Tamb = 25 °C only.
[5] ICC is measured with outputs pulled to VCC or GND.
[6] This is the increase in supply current for each input at the specified voltage level other than VCC or GND.
11. Dynamic characteristics
Table 8. Dynamic characteristics
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 8.
Symbol Parameter
Conditions
Tamb = 40 °C to +85 °C[1]
tPLH
LOW-to-HIGH propagation delay nAn to nY
tPHL
HIGH-to-LOW propagation delay nAn to nY
tPZH
output enable time nOE to nY
tPZL
output enable time nOE to nY
tPHZ
output disable time nOE to nY
tPLZ
output disable time nOE to nY
see Figure 6
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
see Figure 6
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
see Figure 7
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
see Figure 7
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
see Figure 7
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
see Figure 7
VCC = 2.7 V
VCC = 3.0 V to 3.6 V
[1] Typical values are at VCC = 3.3 V and Tamb = 25 °C.
Min Typ Max Unit
-
-
4.5 ns
1.0 2.7 4.0 ns
-
-
4.9 ns
1.0 2.9 3.9 ns
-
-
6.0 ns
1.0 3.4 4.7 ns
-
-
6.5 ns
1.1 3.4 4.7 ns
-
-
5.7 ns
1.8 3.7 5.1 ns
-
-
4.0 ns
1.3 2.6 4.5 ns
74LVT_LVTH125_6
Product data sheet
Rev. 06 — 6 March 2006
© Koninklijke Philips Electronics N.V. 2006. All rights reserved.
7 of 16
 

Share Link: 