Table 1. Specifications
700-*
Temperature
range
Class B and 2B: -70 °C to 500 °C (continuous
operation)
Class A: -30 °C to 300 °C
Leads
Pt-clad Ni wire
Long-term
stability
Vibration
resistance
Shock
resistance
Environmental
conditions
Insulation
resistance
Self heating
max. R0 drift 0.04% after 1000 h at 500 °C
at least 40 g acceleration at 10 Hz to 2000 Hz,
depends on installation
at least 100 g acceleration with 8 ms half sine
wave, depends on installation
unhoused for dry environments only
>100 M at 20 °C; >2 M at 500 °C
0.4 K/mW at 0 °C
Response time
Measuring current
Packaging
water current (v=0.4 m/s): t0.5=0.05 s; t0.9=0.15 s
air stream (V=2 m/s): t0.5=3.0 s; t0.9=10.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
anti-static plastic bag
701-*
Class B and 2B: -70 °C to 500 °C (continuous
operation)
Class A: -30 °C to 300 °C
Pt-clad Ni wire
max. R0 drift 0.04% after 1000 h at 500 °C
at least 40 g acceleration at 10 Hz to 2000 Hz,
depends on installation
at least 100 g acceleration with 8 ms half sine
wave, depends on installation
unhoused for dry environments only
>100 M at 20 °C; >2 M at 500 °C
0.6 K/mW at 0 °C
water current (v=0.4 m/s): t0.5=0.04 s; t0.9=0.12 s
air stream (V=2 m/s): t0.5=2.2 s; t0.9=7.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
anti-static plastic bag
Temperature
range
Soldering
connection
Long-term
stability
Environmental
conditions
Insulation
resistance
Self heating
Response time
Measuring current
Processing
instructions
Packaging
702-*
Class B: -50 °C to 130 °C (continuous operation)
end-termination galvanic tin-plated with Ni barrier
layer
max. R0 drift 0.06 % after 1000 h at 130 °C
unhoused for dry environments only
>100 M at 20 °C; >2 M at 130 °C (glass
covering)
0.8 K/mW at 0 °C
water current (v=0.4 m/s): t0.5=0.10 s; t0.9=0.25 s
air stream (V = 2 m/s): t0.5=2.5 s; t0.9=8.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
face up mounting: reflow soldering or wave
soldering, e.g. double wave ≤8 s/235 °C
face-up in blister reel
703-*
Class B: -50 °C to 130 °C (continuous operation)
end-termination galvanic tin-plated with Ni barrier
layer
max. R0 drift 0.06 % after 1000 h at 130 °C
unhoused for dry environments only
>100 M at 20 °C; >2 M at 130 °C (glass
covering)
0.4 K/mW at 0 °C
water current (v=0.4 m/s): t0.5=0.15 s; t0.9=0.30 s
air stream (V = 2 m/s): t0.5=3.5 s; t0.9=10.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
face up mounting: reflow soldering or wave
soldering, e.g. double wave ≤8 s/235 °C
face-up in blister reel