datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

40HFR160 View Datasheet(PDF) - Vishay Semiconductors

Part Name
Description
View to exact match
40HFR160
Vishay
Vishay Semiconductors Vishay
40HFR160 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
40HF(R) Series
Standard Recovery Diodes, Vishay High Power Products
(Stud Version), 40 A
70
DC
60
180°
120°
90°
50
60°
30°
40
2
1.5 K/W
K/W
3 K/W
30 RMS Limit
Conduction Period
20
40HF(R) Series
10
(1400V, 1600V)
Tj = 160°C
0
0 10 20 30 40 50 60
Average Forward Current (A)
5 K/W
7 K/W
10 K/W
700
40
80
120 160
Maximum Allowable Ambient Temperature (°C)
Fig. 8 - Forward Power Loss Characteristics
550
At Any Rated Load Condition And With
500 Rated Vrrm Applied Following Surge.
Initial Tj = Tj Max.
450
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
400
350
300
250
200
150 40HF(R) Series
100
1
10
100
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Fig. 9 - Maximum Non-Repetitive Surge Current
600
Maximum Non Repetitive Surge Current
550
Versus Pulse Train Duration.
500
Initial Tj = Tj Max.
No Voltage Reapplied
450
Rated Vrrm Reapplied
400
350
300
250
200
150 40HF(R) Series
100
0.01
0.1
1
Pulse Train Duration (s)
Fig. 10 - Maximum Non-Repetitive Surge Current
1000
100
Tj = 25°C
10
Tj = Tj Max.
40HF(R) Series
up to 1200V
1
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
Instantaneous Forward Voltage (V)
Fig. 11 - Forward Voltage Drop Characteristics
(Up To 1200 V)
1000
Tj = Tj Max
100
Tj = 25°C
10
40HF (R) Series
1
0 0.5 1 1.5 2 2.5 3 3.5 4
Instantaneous Forward Voltage (V)
Fig. 12 - Forward Voltage Drop Characteristics
(For 1400 V/1600 V)
Document Number: 93513
Revision: 23-Jun-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com
5
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]