datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

8-1416000-7 View Datasheet(PDF) - Tyco Electronics

Part Name
Description
View to exact match
8-1416000-7
MACOM
Tyco Electronics MACOM
8-1416000-7 Datasheet PDF : 5 Pages
1 2 3 4 5
Automotive Relays
PCB Single Relays
Micro Relay K (THT – THR)
n Small power relay
n Limiting continuous current 30A
n Minimal weight
n Low noise operation
n Wave (THT) and reflow (THR/pin-in-paste) solderable versions
n For twin version refer to Double Micro Relay K
Typical applications
Car alarm, door control, door lock, hazard warning signal, heated front/rear
screen, immobilizer, lamps front/rear/fog light, interior lights, seat control,
sun roof, turn signal, window lifter, wiper control.
086C/R1_fcw1b
Contact Data
Typical applications
Resistive/inductive load
Wiper load
Lamp load5)
V23086-*100*-A403
V23086-*1*02-A803
V23086-***21-A502
Contact arrangement
1 form C, 1 CO
1 form C, 1 CO
1 form A, 1 NO
Rated voltage
10/12VDC
10/12VDC
10/12VDC
NO/NC
NO/NC
Rated current
30/25A
30/25A
30A
Limiting continuous current
23°C
30/25A
30/25A
30A
85°C
20/15A
20/15A
20A
Limiting making current
40A1)
40A1)
100A2)
Limiting breaking current
30A
30A
30A
Contact material
Min. recommended contact load
AgSnO2
1A at 5VDC3)
Initial voltage drop at 10A, typ./max.
30/300mV
Operate/release time
typ. 3/1.5ms4)
Electrical enduranc
cyclic temperature -40°C, +25°C, +85°C
form C contact (CO) at 14VDC
motor reverse blocked,
wiper,
25A, 0.77mH
25A make/5A break,
>1x105 ops.
generator peak,
20A on NC,1mH
>1x106 ops.
form A contact (NO) at 14VDC
resistive 20A
lamp 100A inrush,
>3x105 ops.
10A steady state
>1x105 ops.5)
Mechanical endurance
>5x106 ops.
Max. DC load breaking capacity
1) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5VDC for 12VDC load voltages. For a load current duration of maximum
3s for a make/break ratio of 1:10.
2) Corresponds to the peak inrush current on initial actuation (cold filament).
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) Measured at nominal voltage without coil suppression unit. A low resistive suppression
device in parallel to the relay coil increases the release time and reducesthe lifetime
caused by increased erosion and/or higher risk of contact tack welding.
5) Be aware of using right polarity, see Terminal Assignment. Wrong polarity will reduce
endurance.
Load limit curve 1: arc extinguishes, during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
06-2011, Rev. 0611
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]