KEMET CERAMIC MOLDED/RADIAL — MIL-C-11015 & MIL-PRF-39014
®
STABLE TEMPERATURE CHARACTERISTICS—BX & BR (EIA-X7R)
RATINGS & PART NUMBER REFERENCE
CAP.
pF
TOL.
%
1,200 10
1,500 10
1,500 20
1,800 10
2,200 10
2,200 20
2,700 10
3,300 10
3,300 20
3,900 10
4,700 10
4,700 20
5,600 10
6,800 10
6,800 20
8,200 10
10,000 10
10,000 20
12,000 10
15,000 10
15,000 20
18,000 10
22,000 10
22,000 20
27,000 10
33,000 10
33,000 20
39,000 10
47,000 10
47,000 20
56,000 10
68,000 10
68,000 20
82,000 10
100,000 10
100,000 20
120,000 10
150,000 10
150,000 20
180,000 10
220,000 10
220,000 20
270,000 10
330,000 10
330,000 20
390,000 10
470,000 10
470,000 20
560,000 10
680,000 10
680,000 20
820,000 10
1,000,000 10
1,000,000 20
KEMET
PART NUMBER
MIL-C-11015/19
MIL-PRF-39014/02
MIL-PRF-39014/02 For Failure Rate Levels (2)
M
P
R
S
200 VOLT — C062/C066 SIZE (MILITARY—CK06 or CKR06)
C06(4)(1)122K2X5C(2)
CK06BX122K
CKR06BX122K(2)(3) 1201(3) 1241(3) 1281(3) 1321(3)
C06(4)(1)152K2X5C(2)
CK06BX152K
CKR06BX152K(2)(3) 1202(3) 1242(3) 1282(3) 1322(3)
C06(4)(1)152M2X5C(2)
CK06BX152M
CKR06BX152M(2)(3) 1203(3) 1243(3) 1283(3) 1323(3)
C06(4)(1)182K2X5C(2)
C06(4)(1)222K2X5C(2)
CK06BX182K
CK06BX222K
CKR06BX182K(2)(3) 1204(3) 1244(3) 1284(3) 1324(3)
CKR06BX222K(2)(3) 1206(3) 1246(3) 1286(3) 1326(3)
C06(4)(1)222M2X5C(2)
CK06BX222M
CKR06BX222M(2)(3) 1207(3) 1247(3) 1287(3) 1327(3)
C06(4)(1)272K2X5C(2)
CK06BX272K
CKR06BX272K(2)(3) 1208(3) 1248(3) 1288(3) 1328(3)
C06(4)(1)332K2X5C(2)
CK06BX332K
CKR06BX332K(2)(3) 1209(3) 1249(3) 1289(3) 1329(3)
C06(4)(1)332M2X5C(2)
CK06BX332M
CKR06BX332M(2)(3) 1210(3) 1250(3) 1290(3) 1330(3)
C06(4)(1)392K2X5C(2)
CK06BX392K
CKR06BX392K(2)(3) 1211(3) 1251(3) 1291(3) 1331(3)
C06(4)(1)472K2X5C(2)
C06(4)(1)472M2X5C(2)
CK06BX472K
CK06BX472M
CKR06BX472K(2)(3) 1212(3) 1252(3) 1292(3) 1332(3)
CKR06BX472M(2)(3) 1213(3) 1253(3) 1293(3) 1333(3)
C06(4)(1)562K2X5C(2)
CK06BX562K
CKR06BX562K(2)(3) 1214(3) 1254(3) 1294(3) 1334(3)
C06(4)(1)682K2X5C(2)
CK06BX682K
CKR06BX682K(2)(3) 1215(3) 1255(3) 1295(3) 1335(3)
C06(4)(1)682M2X5C(2)
CK06BX682M
CKR06BX682M(2)(3) 1216(3) 1256(3) 1296(3) 1336(3)
C06(4)(1)822K2X5C(2)
CK06BX822K
CKR06BX822K(2)(3) 1217(3) 1257(3) 1297(3) 1337(3)
C06(4)(1)103K2X5C(2)
CK06BX103K
CKR06BX103K(2)(3) 1218(3) 1258(3) 1298(3) 1338(3)
C06(4)(1)103M2X5C(2)
CK06BX103M
CKR06BX103M(2)(3) 1219(3) 1259(3) 1299(3) 1339(3)
100 VOLT — C062/C066 SIZE (MILITARY—CK06 or CKR06)
C06(4)(1)123K1X5C(2)
C06(4)(1)153K1X5C(2)
CK06BX123K
CK06BX153K
CKR06BX123K(2)(3) 1231(3)
CKR06BX153K(2)(3) 1220(3)
C062K153M1X5CA
C06(4)(1)183K1X5C(2)
CK06BX153M
CK06BX183K
CKR06BX183K(2)(3) 1221(3)
C06(4)(1)223K1X5C(2)
C062K223M1X5CA
CK06BX223K
CK06BX223M
CKR06BX223K(2)(3) 1222(3)
C06(4)(1)273K1X5C(2)
C06(4)(1)333K1X5C(2)
CK06BX273K
CK06BX333K
CKR06BX273K(2)(3) 1232(3)
CKR06BX333K(2)(3) 1223(3)
C062K333M1X5CA
C06(4)(1)393K1X5C(2)
CK06BX333M
CK06BX393K
CKR06BX393K(2)(3) 1224(3)
C06(4)(1)473K1X5C(2)
C062K473M1X5CA
CK06BX473K
CK06BX473M
CKR06BX473K(2)(3) 1225(3)
C06(4)(1)563K1X5C(2)
C06(4)(1)683K1X5C(2)
CK06BX563K
CK06BX683K
CKR06BX563K(2)(3) 1226(3)
CKR06BX683K(2)(3) 1227(3)
C062K683M1X5CA
C06(4)(1)823K1X5C(2)
CK06BX683M
CK06BX823K
CKR06BX823K(2)(3) 1229(3)
C06(4)(1)104K1X5C(2)
C062K104M1X5CA
CK06BX104K
CK06BX104M
CKR06BX104K(2)(3) 1230(3)
1271(3) 1311(3) 1351(3)
1260(3) 1300(3) 1340(3)
1261(3) 1301(3) 1341(3)
1262(3) 1302(3) 1342(3)
1272(3) 1312(3) 1352(3)
1263(3) 1303(3) 1343(3)
1264(3) 1304(3) 1344(3)
1265(3) 1305(3) 1345(3)
1266(3) 1306(3) 1346(3)
1267(3) 1307(3) 1347(3)
1269(3) 1309(3) 1349(3)
1270(3) 1310(3) 1350(3)
50 VOLT — C062/C066 SIZE (MILITARY—CK06 or CKR06)
C06(4)(1)124K5X5C(2)
CK06BX124K
CKR06BX124K(2)(3) 1233(3)
C06(4)(1)154K5X5C(2)
CK06BX154K
CKR06BX154K(2)(3) 1234(3)
C062K154M5X5CA
CK06BX154M
C06(4)(1)184K5X5C(2)
CK06BX184K
CKR06BX184K(2)(3) 1235(3)
C06(4)(1)224K5X5C(2)
CK06BX224K
CKR06BX224K(2)(3) 1236(3)
C062K224M5X5CA
CK06BX224M
C06(4)(1)274K5X5C(2)
CK06BX274K
CKR06BX274K(2)(3) 1237(3)
C06(4)(1)334K5X5C(2)
CK06BX334K
CKR06BX334K(2)(3) 1238(3)
C062K334M5X5CA
CK06BX334M
C06(4)(1)394K5X5C(2)
CK06BX394K
CKR06BX394K(2)(3) 1239(3)
C06(4)(1)474K5X5C(2)
CK06BX474K
CKR06BX474K(2)(3) 1240(3)
C062K474M5X5CA
CK06BX474M
C06(4)(1)564K5X5C(2)
CK06BX564K
CKR06BX564K(2)(3) 1404(3)
C06(4)(1)684K5X5C(2)
CK06BX684K
CKR06BX684K(2)(3) 1405(3)
C062K684M5X5CA
CK06BX684M
C06(4)(1)824K5X5C(2)
CK06BX824K
CKR06BX824K(2)(3) 1406(3)
C06(4)(1)105K5X5C(2)
CK06BX105K
CKR06BX105K(2)(3) 1407(3)
C062K105M5X5CA
CK06BX105M
1273(3) 1313(3) 1353(3)
1274(3) 1314(3) 1354(3)
1275(3) 1315(3) 1355(3)
1276(3) 1316(3) 1356(3)
1277(3) 1317(3) 1357(3)
1278(3) 1318(3) 1358(3)
1279(3) 1319(3) 1359(3)
1280(3) 1320(3) 1360(3)
1408(3) 1412(3) 1416(3)
1409(3) 1413(3) 1417(3)
1410(3) 1414(3) 1418(3)
1411(3) 1415(3) 1419(3)
(1) Insert proper letter for specification: K — MIL-C-11015; T — MIL-PRF-39014.
(2) Failure Rate Designator: A — Not applicable (MIL-C-11015); M — 1%/1000 Hours, P — .1%/1000 Hours, R — .01%/1000 Hours, S — .001%/1000 Hours (MIL-PRF-39014)
(3) Add “V” for stand-off design (C066). Leave blank for the flat bottom design (C062).
(4) Insert “2” for standard design (Style C062). Insert “6” for stand-off design (Style C066). Note: Stand-offs are available only with the CKR, not the CK.
KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300