TPA3002D2
SLOS402C − DECEMBER 2002 − REVISED JANUARY 2004
THERMAL RESISTANCE
vs
THERMAL VIA QUANTITY 2-LAYER PCB
25
www.ti.com
24
23
22
21
20
4
6
8
10
12
14
16
Thermal Via Quantity (13 Mil Diameter)
Figure 39. Thermal Resistance
BASIC MEASUREMENT SYSTEM
This application note focuses on methods that use the basic equipment listed below:
D Audio analyzer or spectrum analyzer
D Digital multimeter (DMM)
D Oscilloscope
D Twisted pair wires
D Signal generator
D Power resistor(s)
D Linear regulated power supply
D Filter components
D EVM or other complete audio circuit
Figure 40 shows the block diagrams of basic measurement systems for class-AB and class-D amplifiers. A sine
wave is normally used as the input signal since it consists of the fundamental frequency only (no other
harmonics are present). An analyzer is then connected to the APA output to measure the voltage output. The
analyzer must be capable of measuring the entire audio bandwidth. A regulated dc power supply is used to
reduce the noise and distortion injected into the APA through the power pins. A System Two audio measurement
system (AP-II) (Reference 1) by Audio Precision includes the signal generator and analyzer in one package.
The generator output and amplifier input must be ac-coupled. However, the EVMs already have the ac-coupling
capacitors, (CIN), so no additional coupling is required. The generator output impedance should be low to avoid
attenuating the test signal, and is important since the input resistance of APAs is not very high (about 10 k).
Conversely the analyzer-input impedance should be high. The output impedance, ROUT, of the APA is normally
in the hundreds of milliohms and can be ignored for all but the power-related calculations.
Figure 40(a) shows a class-AB amplifier system. They take an analog signal input and produce an analog signal
output. These amplifier circuits can be directly connected to the AP-II or other analyzer input.
This is not true of the class-D amplifier system shown in Figure 40(b), which requires low pass filters in most
cases in order to measure the audio output waveforms. This is because it takes an analog input signal and
converts it into a pulse-width modulated (PWM) output signal that is not accurately processed by some
analyzers.