datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

FX805LG View Datasheet(PDF) - CML Microsystems Plc

Part Name
Description
View to exact match
FX805LG
CML
CML Microsystems Plc CML
FX805LG Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Controlling Protocol ......
“Write to CTCSS Tx Frequency/NRZ Baud Rate Register” – A/C 73 (7B ), followed by 2 bytes of
H
H
Command Data.
The information loaded to this register will set either the:
(a) CTCSS Tx Tone Frequency
f
CTCSS OUT
(b) NRZ Tx Baud Rate
R
NRZ Tx
(c) NRZ Rx Baud Rate
RNRZ Rx
The chosen mode for this register (a, b or c) is determined by the FX805 operational mode enabled by the Control Register
(Table 3), as shown in the table below.
Control Register Bits
765
FX805 Mode
Enabled
CTCSS Tx/NRZ Baud Rate
Register Function
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
CTCSS Decode
NRZ Decode
CTCSS Encode
NRZ Encode
CTCSS Encode and Decode
NRZ Encode and CTCSS Decode
NRZ and CTCSS Decode
NRZ Decode
NRZ Rx Baud Rate
CTCSS Tx Frequency
NRZ Tx Baud Rate
CTCSS Tx Frequency
NRZ Tx Baud Rate
NRZ Rx Baud Rate
NRZ Rx Baud Rate
Table 5 CTCSS Frequency/NRZ Baud Rate Register Configurations
Data Format
Data is transmitted, via “C-BUS,” to this register as 2 bytes of Command Data (1 and 2) distributed as command words P and
Q, in the form illustrated in Figure 7. This register is not affected by the General Reset command (01 ) and may adopt any
H
random configuration at Power-Up.
(COMMAND DATA)
(MSB) – LOADED FIRST
Byte 1
15 14 13 12 11 10 9 8
P
“0”
Byte 0
(COMMAND DATA)
(LSB) – LOADED LAST
7654 321 0
Q
Fig.7 Format of the CTCSS Tx Frequency/NRZ Baud Rate Register
Command Words P and Q
With reference to Figure 7, the two data words, P and Q, loaded to this register are interpreted as:
P = a binary number to set the Tx Sub-Audio Lowpass Filter bandwidth (applicable to NRZ Encode and CTCSS
Encode modes).
Q = a binary number to set the frequency or baud rate of the selected function (see Table 5).
Command Word ‘P’
Bits
LSB
15 14 13 12
‘P’
00 1 0
2
00 1 1
3
01 0 0
4
01 0 1
5
01 1 0
6
01 1 1
7
10 0 0
8
Table 6 Valid Values of ‘P’
LPF Bandwidth
300Hz
200Hz
150Hz
120Hz
100Hz
85.7Hz
75Hz
Bits 12 to 15 are used to produce the data word ‘P’ as
shown in Table 6 (left). The cut-off frequency f (0.5dB
CO
point) of the Tx Sub-Audio Lowpass Filter is calculated as:
f=
CO
f
XTAL
32 x 208.33 x ‘P’
so ‘P’ =
fXTAL
32 x 208.33 x f
CO
Table 6 is given as an example and calculated using a Xtal/
clock (f ) frequency of 4.00MHz. As illustrated, only values
XTAL
of ‘P’ of 2 to 8 are usable.
10
 