ABSOLUTE MAXIMUM RATINGS1
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+15 V
Input Voltage2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +15 V
Differential Input Voltage2 . . . . . . . . . . . . . . . . . . . . . . . +15 V
Output Short Circuit Duration . . . . . . . . . . . . . . . . . Indefinite
Storage Temperature Range
P, S, RU Package . . . . . . . . . . . . . . . . . . . . –65°C to +150°C
Operating Temperature Range
OP196G, OP296G, OP496G, H . . . . . . . – 40°C to +125°C
Junction Temperature Range
P, S, RU Package . . . . . . . . . . . . . . . . . . . – 65°C to +150°C
Lead Temperature Range (Soldering, 60 sec) . . . . . . . +300°C
Package Type
JA3
8-Lead Plastic DIP
103
8-Lead SOIC
158
8-Lead TSSOP
240
14-Lead Plastic DIP
83
14-Lead SOIC
120
14-Lead TSSOP
180
JC
Units
43
°C/W
43
°C/W
43
°C/W
39
°C/W
36
°C/W
35
°C/W
NOTES
1Absolute maximum ratings apply to both DICE and packaged parts, unless
otherwise noted.
2For supply voltages less than +15 V, the absolute maximum input voltage is
equal to the supply voltage.
3θJA is specified for the worst case conditions, i.e., θJA is specified for device in
socket for P-DIP package; θJA is specified for device soldered in circuit board
for SOIC and TSSOP packages.
OP196/OP296/OP496
ORDERING GUIDE
Model
Temperature
Range
OP196GP –40°C to +125°C
OP196GS –40°C to +125°C
OP296GP –40°C to +125°C
OP296GS –40°C to +125°C
OP296HRU –40°C to +125°C
OP496GP –40°C to +125°C
OP496GS –40°C to +125°C
OP496HRU –40°C to +125°C
Package
Description
Package
Option
8-Lead Plastic DIP N-8
8-Lead SOIC
SO-8
8-Lead Plastic DIP N-8
8-Lead SOIC
SO-8
8-Lead TSSOP
RU-8
14-Lead Plastic DIP N-14
14-Lead SOIC
SO-14
14-Lead TSSOP RU-14
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the OP196/OP296/OP496 feature proprietary ESD protection circuitry, permanent
damage may occur on devices subjected to high energy electrostatic discharges. Therefore, pro per
ESD precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE