74LVX240
Table 6: DC Specifications
Test Condition
Value
Symbol
Parameter
VIH High Level Input
Voltage
VIL Low Level Input
Voltage
VOH High Level Output
Voltage
VOL Low Level Output
Voltage
IOZ High Impedance
Output Leakage
Current
II
Input Leakage
Current
ICC Quiescent Supply
Current
VCC
TA = 25°C
-40 to 85°C -55 to 125°C Unit
(V)
Min. Typ. Max. Min. Max. Min. Max.
2.0
1.5
1.5
1.5
3.0
2.0
2.0
2.0
V
3.6
2.4
2.4
2.4
2.0
0.5
0.5
0.5
3.0
0.8
0.8
0.8 V
3.6
0.8
0.8
0.8
2.0
IO=-50 µA
1.9 2.0
1.9
1.9
3.0
IO=-50 µA
2.9 3.0
2.9
2.9
V
3.0
IO=-4 mA
2.58
2.48
2.44
2.0
IO=50 µA
0.0 0.1
0.1
0.1
3.0
IO=50 µA
0.0 0.1
0.1
0.1 V
3.0
IO=4 mA
0.36
0.44
0.55
3.6
VI = VIH or VIL
VO = VCC or GND
±0.25
± 2.5
± 2.5 µA
3.6 VI = 5.5V or GND
± 0.1
±1
± 1 µA
3.6 VI = VCC or GND
4
40
40 µA
Table 7: Dynamic Switching Characteristics
Test Condition
Value
Symbol
Parameter
VCC
(V)
VOLP Dynamic Low
Voltage Quiet
3.3
VOLV Output (note 1, 2)
Dynamic High
VIHD Voltage Input
3.3
(note 1, 3)
Dynamic Low
VILD Voltage Input
3.3
(note 1, 3)
CL = 50 pF
TA = 25°C
-40 to 85°C -55 to 125°C Unit
Min. Typ. Max. Min. Max. Min. Max.
0.3 0.5
-0.5 -0.3
2.0
V
0.8
1) Worst case package.
2) Max number of outputs defined as (n). Data inputs are driven 0V to 3.3V, (n-1) outputs switching and one output at GND.
3) Max number of data inputs (n) switching. (n-1) switching 0V to 3.3V. Inputs under test switching: 3.3V to threshold (VILD), 0V to threshold
(VIHD), f=1MHz.