IAA110P
PERFORMANCE DATA*
IAA110P
Typical LED Forward Voltage Drop
(N = 50, TA = 25°C, IF = 5mA)
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
IAA110P
Typical On-Resistance Distribution
(N = 50, TA = 25°C, IL = 100mADC, IF = 5mA)
35
30
25
20
15
10
5
0
18.75 19.85 20.95 22.05 23.15 24.25 25.35
On-Resistance (Ω)
IAA110P
Typical Blocking Voltage Distribution
(N = 50, TA = 25°C)
35
30
25
20
15
10
5
0
377.5 388.5 399.5 410.5 421.5 432.5 443.5
Blocking Voltage (VP)
IAA110P
Typical IF for Switch Operation
(N = 50, TA = 25°C, IL = 100mADC)
25
IAA110P
Typical IF for Switch Dropout
(N = 50, TA = 25°C, IL = 100mADC)
25
IAA110P
Typical Turn-On Time
(N
25
=
50,
TA
=
25°C,
IL
=
100mADC,
IF
=
5mA)
20
20
20
15
15
15
10
10
10
5
5
5
0
0.39 0.65 0.91 1.17 1.43 1.69 1.95
LED Current (mA)
0
0.39 0.65 0.91 1.17 1.43 1.69 1.95
LED Current (mA)
0
0.3 0.9 1.5 2.1 2.7 3.3 3.9
Turn-On (ms)
IAA110P
Typical Turn-Off Time
(N = 50, TA = 25°C, IL = 100mADC, IF = 5mA)
25
20
15
10
5
0
0.05 0.15 0.25 0.35 0.45 0.55 0.65
Turn-Off (ms)
IAA110P
Typical Load Current vs. Temperature
180
160
140
120
100
80
60
IIIFFF===21500mmmAAA
40
20
0
-40 -20 0 20 40 60 80 100 120
Temperature (°C)
IAA110P
Typical Leakage vs. Temperature
(Measured across Pins 14 & 16 or 11 & 13)
0.016
0.014
0.012
0.010
0.008
0.006
0.004
0.002
0
-40 -20
0 20 40 60
Temperature (°C)
80 100
IAA110P
Typical Blocking Voltage vs. Temperature
430
425
420
415
410
405
400
395
-40 -20
0 20 40 60
Temperature (°C)
80 100
IAA110P
Typical Turn-On vs. Temperature
5.0
(IL = 100mADC)
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
-40 -20 0
20 40 60
IF=5mA
IF=10mA
IF=20mA
80 100
Temperature (°C)
IAA110P
Typical Turn-Off vs. Temperature
1.0
(IL = 100mADC)
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
IF=5mA
0
-40 -20 0
20 40 60
80 100
Temperature (°C)
* The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
R03
www.clare.com