datasheetbank_Logo   Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site
Part Name :   

TL031MJG View Datasheet(PDF) - Texas Instruments

Part NameDescriptionManufacturer
TL031MJG ENHANCED-JFET LOW-POWER LOW-OFFSET OPERATIONAL AMPLIFIERS Texas-Instruments
Texas Instruments Texas-Instruments
TL031MJG Datasheet PDF : 67 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
TL03x, TL03xA
ENHANCED-JFET LOW-POWER LOW-OFFSET
OPERATIONAL AMPLIFIERS
SLOS180C − FEBRUARY 1997 − REVISED DECEMBER 2001
TL034C and TL034AC electrical characteristics at specified free-air temperature
TL034C, TL034AC
PARAMETER
TEST CONDITIONS
TA
VCC± = ±5 V
VCC± = ±15 V
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
VO = 0,
VIC = 0,
RS = 50 Ω
TL034C
TL034AC
25°C
Full range
25°C
Full range
0.91
6
8.2
0.7 3.5
5.7
0.79
4
6.2
mV
0.58 1.5
3.7
aVIO
Temperature coefficient
of input offset voltage
VO = 0,
VIC = 0,
RS = 50 Ω
TL034C
TL034AC
25°C to
70°C
25°C to
70°C
11.6
11.6
12
μV/°C
12
25
Input offset voltage
long-term drift
IIO
Input offset current
VO = 0,
VIC = 0,
RS = 50 Ω
VO = 0, VIC = 0
See Figure 5
25°C
25°C
70°C
0.04
1 100
9 200
0.04
μV/mo
1 100
pA
12 200
IIB
Input bias current
VO = 0, VIC = 0
See Figure 5
25°C
70°C
2 200
50 400
2 200
pA
80 400
VICR
Common-mode input
voltage range
25°C
−1.5 −3.4
to 4 to 5.4
−11.5 −13.4
to 14 to 15.4
V
Full range
−1.5
to 4
−11.5
to 14
VOM+
Maximum positive peak
output voltage swing
RL = 10 kΩ
25°C
0°C
70°C
3 4.3
3 4.2
3 4.3
13
14
13
14
V
13
14
VOM−
Maximum negative peak
output voltage swing
RL = 10 kΩ
25°C
−3 −4.2
−12.5 −13.9
0°C
−3 −4.1
−12.5 −13.9
V
70°C
−3 −4.2
−12.5 −14
AVD
Large-signal differential
voltage amplification§
RL = 10 kΩ
ri
Input resistance
ci
Input capacitance
Common-mode
CMRR rejection ratio
VIC = VICRmin,
VO = 0,
RS = 50 Ω
25°C
0°C
70°C
25°C
25°C
25°C
0°C
70°C
4
12
3 11.1
4 13.3
1012
5
70
87
70
87
70
87
5 14.3
4 13.5
5 15.2
1012
14
75
94
75
94
75
94
V/mV
Ω
pF
dB
kSVR
Supply-voltage
rejection ratio
(ΔVCC±/ΔVIO)
VO = 0, RS = 50 Ω
25°C
0°C
70°C
75
96
75
96
75
96
75
96
75
96
dB
75
96
Full range is 0°C to 70°C.
Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to
TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
§ At VCC± = ±5 V, VO = ±2.3 V; at VCC± = ±15 V, VO = ±10 V
18
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Direct download click here
 

Share Link : Texas-Instruments
All Rights Reserved © datasheetbank.com 2014 - 2019 [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]