TL03x, TL03xA
ENHANCED-JFET LOW-POWER LOW-OFFSET
OPERATIONAL AMPLIFIERS
SLOS180C − FEBRUARY 1997 − REVISED DECEMBER 2001
TL032M and TL032AM electrical characteristics at specified free-air temperature
PARAMETER
TEST CONDITIONS
TL032M, TL032AM
TA
VCC± = ±5 V
VCC± = ±15 V
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
VO = 0,
VIC = 0,
RS = 50 Ω
TL032M
TL032AM
25°C
Full range
25°C
Full range
0.69 3.5
6.5
0.53 2.8
5.8
0.57 1.5
4.5
mV
0.39 0.8
3.8
aVIO
Temperature coefficient
of input offset voltage
VO = 0,
VIC = 0,
RS = 50 Ω
TL032M
TL032AM
25°C to
125°C
25°C to
125°C
9.7
9.7
9.7
μV/°C
9.7
Input offset voltage
long-term drift
IIO
Input offset current
VO = 0,
VIC = 0,
RS = 50 Ω
VO = 0,
VIC = 0
See Figure 5
25°C
25°C
125°C
0.04
1 100
0.2
10
0.04
μV/mo
1 100 pA
0.2
10 nA
IIB
Input bias current
VO = 0,
VIC = 0
See Figure 5
25°C
125°C
2 200
7
20
2 200 pA
8
20 nA
VICR
Common-mode input
voltage range
25°C
−1.5 −3.4
to 4 to 5.4
−11.5 −13.4
to 14 to 15.4
V
Full range
−1.5
to 4
−11.5
to 14
Maximum positive peak
VOM+ output voltage swing
RL = 10 kΩ
25°C
−55°C
125°C
3 4.3
3 4.1
3 4.4
13
14
13
14
V
13
14
Maximum negative peak
VOM− output voltage swing
RL = 10 kΩ
25°C
−3 −4.2
−12.5 −13.9
−55°C
−3
−4
−12.5 −13.8
V
125°C
−3 −4.3
−12.5 −14
AVD
Large-signal differential
voltage amplification§
RL = 10 kΩ
ri
Input resistance
ci
Input capacitance
CMRR
Common-mode rejection
ratio
VIC = VICRmin,
VO = 0, RS = 50 Ω
25°C
−55°C
125°C
25°C
25°C
25°C
−55°C
125°C
4
12
3 7.1
3 12.9
1012
5
70
87
70
87
70
87
5 14.3
4 10.4
4
15
1012
4
75
94
70
94
70
94
V/mV
Ω
pF
dB
kSVR
Supply-voltage
rejection ratio
(ΔVCC±/ΔVIO)
VCC± = ±5 V to ±15 V,
VO = 0, RS = 50 Ω
25°C
−55°C
125°C
75
96
75
95
75
96
75
96
75
95
dB
75
96
Full range is −55°C to 125°C.
Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to
TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
§ At VCC± = ±5 V, VO = 2.3 V; at VCC± = ±15 V, VO = ±10 V