L7800 SERIES
ELECTRICAL CHARACTERISTICS OF L7812 (refer to the test circuits, TJ = -55 to 150°C, VI = 19V,
IO = 500 mA, CI = 0.33 µF, CO = 0.1 µF unless otherwise specified).
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
VO Output Voltage
VO Output Voltage
VO(*) Line Regulation
VO(*) Load Regulation
Id Quiescent Current
Id Quiescent Current Change
VO/T Output Voltage Drift
eN Output Noise Voltage
SVR Supply Voltage Rejection
Vd Dropout Voltage
RO Output Resistance
Isc Short Circuit Current
Iscp Short Circuit Peak Current
TJ = 25°C
IO = 5 mA to 1 A PO 15W
VI = 15.5 to 27 V
VI = 14.5 to 30 V
TJ = 25°C
VI = 16 to 22 V
TJ = 25°C
IO = 5 mA to 1.5 A
TJ = 25°C
IO = 250 to 750 mA
TJ = 25°C
TJ = 25°C
IO = 5 mA to 1 A
VI = 15 to 30 V
IO = 5 mA
B =10Hz to 100KHz
TJ = 25°C
VI = 15 to 25 V
f = 120Hz
IO = 1 A
TJ = 25°C
f = 1 KHz
VI = 35 V
TJ = 25°C
TJ = 25°C
11.5 12 12.5
V
11.4 12 12.6
V
120 mV
60
100 mV
60
6
mA
0.5 mA
0.8
1.5
mV/°C
40 µV/VO
61
dB
2
2.5
V
18
m
0.75 1.2
A
1.3
2.2
3.3
A
(*) Load and line regulation are specified at constant junction temperature. Changes in VO due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.
ELECTRICAL CHARACTERISTICS OF L7815 (refer to the test circuits, TJ = -55 to 150°C, VI = 23V,
IO = 500 mA, CI = 0.33 µF, CO = 0.1 µF unless otherwise specified).
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
VO Output Voltage
VO Output Voltage
VO(*) Line Regulation
VO(*) Load Regulation
Id Quiescent Current
Id Quiescent Current Change
VO/T Output Voltage Drift
eN Output Noise Voltage
SVR Supply Voltage Rejection
Vd Dropout Voltage
RO Output Resistance
Isc Short Circuit Current
Iscp Short Circuit Peak Current
TJ = 25°C
IO = 5 mA to 1 A PO 15W
VI = 18.5 to 30 V
VI = 17.5 to 30 V
TJ = 25°C
VI = 20 to 26 V
TJ = 25°C
IO = 5 mA to 1.5 A
TJ = 25°C
IO = 250 to 750 mA
TJ = 25°C
TJ = 25°C
IO = 5 mA to 1 A
VI = 18.5 to 30 V
IO = 5 mA
B =10Hz to 100KHz
TJ = 25°C
VI = 18.5 to 28.5 V
f = 120Hz
IO = 1 A
TJ = 25°C
f = 1 KHz
VI = 35 V
TJ = 25°C
TJ = 25°C
14.4 15 15.6
V
14.25 15 15.75 V
150 mV
75
150 mV
75
6
mA
0.5 mA
0.8
1.8
mV/°C
40 µV/VO
60
dB
2
2.5
V
19
m
0.75 1.2
A
1.3
2.2
3.3
A
(*) Load and line regulation are specified at constant junction temperature. Changes in VO due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.