Manual Switches
Flat Base Sealed Toggles and Rockers
NT Series
UL AND CSA ELECTRICAL RATINGS
Rating Code*
Electrical Rating
L192
10 amps, 125, 250, 277 VAC; 14 Hp, 125 VAC; 12 Hp, 250, 277 VAC; 3 amps,
125 VAC ‘‘L’’
L191
15 amps, 125, 250, 277 VAC; 12 Hp, 125 VAC; 1 Hp, 250, 277 VAC; 5 amps,
125 VAC ‘‘L’’
ELECTRICAL RATINGS
FEATURES
ɀ Sealed switching chamber
ɀ 1 or 2-pole circuitry
ɀ 2 or 3 position maintained and
momentary action
ɀ Flat base with quick-connect
terminals – mating connectors are
available
ɀ Spring-loaded actuating mechanism
provides tactile feedback
ɀ High impact strength, non-tracking
case enhances electrical stability
ɀ Temperature range: –40 to 71°C (–40
to 160°F)
ɀ UL Recognized, File E12252, vol. 1,
section 44
ɀ CSA Certified, File LR4442
ɀ CE approved
GENERAL INFORMATION
MICRO SWITCH NT Series toggle switches
are designed to meet severe environment
application needs for rugged, cost-effective
manual switches. These flat base style
products are identical to the stepped
base style in construction and features.
In Amperes
Rating
Code
1
2
3
4
28 Volts DC
Ind. Res. Lamp
12 20
5
10 15
4
15 20
7
10 18
5
115 VDC
Res.
0.75
0.75
0.75
0.75
250 VDC
Res.
0.5
0.5
0.5
0.5
115 Volts AC
60 & 400 Hz
Ind. Res. Lamp
10 15
3
7
15
2
15 15
4
8
11
2
230 VAC
Res.
6
6
6
6
Application Note: Honeywell MICRO SWITCH does not recommend the use of silver
cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally
loads less than 12 volts and/or 0.5 amp. NT switches use silver cadmium oxide
contacts. For other options, contact the MICRO SWITCH Application Center at
1-800-537-6945.
The flat base allows for PC board or con-
nector use for easy wiring/connection.
The flat base NT toggle switches are
provided with quick-connect (spade)
termination. Mating connectors are
available.
TERMINAL CIRCUIT IDENTIFICATION
Terminal identifications are referenced in
the order guides to indicate which circuits
are made in each toggle position (e.g.
‘‘1-2’’ refers to circuit closure through ter-
minals 1 and 2).
112
Honeywell ɀ MICRO SWITCH Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada
 