datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

AK4712EN_ View Datasheet(PDF) - Asahi Kasei Microdevices

Part Name
Description
View to exact match
AK4712EN_
AKM
Asahi Kasei Microdevices AKM
AK4712EN_ Datasheet PDF : 32 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
[AKD4712-A]
2-1. [Repeat Test]: Repeat Test Dialog
Click the [Repeat Test] button in the Tool tab to open the repeat test dialog shown below.
A write repeat test can be executed by this dialog.
Figure 6. [Repeat Test] window
[Start] Button
: Start repeat test.
A dialog for saving a file of the test result will open when this button is clicked.
Name the file.
Test will start after inserting a filename.
[Close] Button
: Close dialog and finish process.
[Address] Box
: Input write data address in hexadecimal numbers.
[Start Data] Box : Input start data in hexadecimal numbers.
[End Data] Box
: Input end data in hexadecimal numbers.
[Step] Box
: Input data write step interval.
[Repeat Count] Box : Input number of repeat cycles for the test writing.
[Up and Down] Box : Data write flow is changed as below.
• Checked: Writes in step interval from the start data to the end data and turns back at the end data to the
start data.
[Example] Start Data = 00, End Data = 05, Step = 1, [ ]…for 1 count.
Data flow: [000102030405050403020100] x Repeat Count Number
• Not checked: Writes in step interval from the start data to the end data and finishes writing.
[Example] Start Data = 00, End Data = 05, Step = 1, [ ]…for 1 count.
Data flow: [000102030405] x Repeat Count Number
[Sampling Frequency] Box: Select sampling frequency from 44.1kHz/48kHz
[Count] Box
: Indicates the count number during a repeat test.
[Lch Level] Box : Indicates the Lch Level during a repeat test.
<KM111300>
-11-
2012/06
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]