General Purpose Relays
Accessories Industrial Power Relay RT / RP / SR2M
I For Industrial Power Relay RT / RP / SR2M,
pinnings 3.5mm / 5mm; relay heights 15.7 / 25.5mm
I Din-rail socket with logical setup of connections (input/output)
I New retainer clip with ejection function
I Easy replacement of relays on a densely packed DIN rail
I High quality rising clamp terminals
I Captive combination terminal screws
I No reduction of protection class or creepage/clearance with
plastic retainer
I Simple plug-in indicator- and protection modules
I White snap-on marking tags
I RoHS compliant (Directive 2002/95/EC)
F0228-B
Socket with screw-type terminals for DIN rail mounting
RT 78 724 Socket with screw-type terminals, pinning 3.5 mm for DIN rail mounting
F0261-A
RT 78 726 Socket with screw-type terminals, pinning 5 mm for DIN rail mounting
S0416-AA
F0262-A
S0416-AB
Approvals
V Z REG.-Nr. 6106 in preparation,
E135149
Technical data
Rated current
Rated voltage / max.switching voltage AC
Dielectric strength coil-contact circuit
open contact circuit
adjacent contact circuits
Clearance / creepage coil-contact circuit
RT 78 724 / RT 78 726
12 A *)
240/400 VAC
4000 Vrms
1000 Vrms
2500 Vrms
RT: W 10 / 10 mm; RP, SR2M: W 8 / 8 mm
*) For 1 pole relays (16 A) the relay
terminals 11-21, 12-22 and 14-24 have to
be bridged.
For 1 pole relays (12 A) the relay terminals
11-12-14 have to be connected to the
socket terminals 21-12-24
I Not suitable for bistable relays with 2 coils!
1
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
1
‘Schrack’ section.
Specifications subject to
change.
 