General Purpose Relays
Accessories
Accessories Industrial Power Relay RT (Continued)
Socket with screw-type terminals for DIN rail mounting
RT 78 724 Socket with screw-type terminals, pinning 3.5 mm
for DIN rail mounting
RT 78 726 Socket with screw-type terminals, pinning 5 mm for
DIN rail mounting, logical terminal arrangement
n DIN-rail socket with logical setup of connections (input/output)
n High quality rising clamp terminals
n Captive combination terminal screws
n Jumper bars for interconnection
RT 78 724
RT 78 726
F0261-C
Z
RT 78 725 Socket with screw-type terminals, pinning 5 mm for
DIN rail mounting, conventional terminal arrangement
n Conventional terminal arrangement
S0416-CA
SCHRACK
S0416-CB
Approvals
VDE Cert. No. 40007571, cULus E135149
F0284-B
Z
S0540-BT
Technical data
RT78724/RT78726 RT78725
Rated voltage/Max. switching voltage AC
240/400 VAC
Rated current 12 A, 2 x 8 A, 16 A*)
Dielectric strength
coil-contact circuit
open contact circuit
adjacent contact circuits
Clearance / creepage
5000 Vrms
1000 Vrms
2500 Vrms
4000 Vrms
1000 Vrms
2500 Vrms
coil-contact circuit
≥ 10/10 mm ≥ 4.7/4.7 mm
Material group of insulation parts
IIIa
Flammability class UL 94
V-0
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
reinforced basic
open contact circuit
functional
adjacent contact circuits
functional
Rated insulation voltage
250 V
Pollution degree
2
Rated voltage system
230 / 400 V
Overvoltage category
III
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
*) For 1 pole relays (16 A) the relay terminals 11-21, 12-22 and 14-24 have to be bridged.
For 1 pole relays (12 A) the relay terminals 11-12-14 have to be connected to the socket
terminals 21-12-14.
08-2017, Rev. 0817
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
n Not suitable for bistable relays with 2 coils!
3
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]