datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

NE1617A View Datasheet(PDF) - NXP Semiconductors.

Part Name
Description
View to exact match
NE1617A Datasheet PDF : 30 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
NXP Semiconductors
NE1617A
Temperature monitor for microprocessor systems
Table 6. Temperature data format (2’s complement)
Temperature (C)
Digital output (8 bits)
+127
0111 1111
+126
0111 1110
+100
0110 0100
+50
0011 0010
+25
0001 1001
+1
0000 0001
0
0000 0000
1
1111 1111
25
1110 0111
50
1100 1110
65
1011 1111
8.3.4 Conversion rate register
The conversion rate register is used to store programmable conversion data, which
defines the time interval between conversions in standard free-running auto-convert
mode. Table 7 shows all applicable data and rates for the device. Only three LSB bits of
the register are used and other bits are reserved for future use. This register can be
written to and read back over the SMBus using commands of the registers named WCR
and RCR, respectively. The POR default conversion data is 02h (0.25 Hz).
Notice that the average supply current, as well as the device power consumption, is
increased with the conversion rate.
Table 7. Conversion rate control byte
Data
00h
Conversion rate (Hz)
0.0625
Average supply current (A typical at VDD = 3.3 V)
67
01h
0.125
68
02h
0.25
70
03h
0.5
75
04h
1
80
05h
2
95
06h
4
125
07h
8
180
08h to FFh (reserved)
n/a
8.3.5 Temperature limit registers
The device has four registers to be used for storing programmable temperature limits,
including the high limit and the low limit for each channel of the external and internal
diodes. Data of the temperature register (RIT and RET) for each channel are compared
with the contents of the temperature limit registers of the same channel, resulting in alarm
conditions. If measured temperature either equals or exceeds the corresponding
temperature limits, an Alert interrupt is asserted and the corresponding flag bit in the
status register is set. The temperature limit registers can be written to and read back using
NE1617A
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 5 — 20 March 2012
© NXP B.V. 2012. All rights reserved.