W25Q32FW
8.2.22 Release Power-down / Device ID (ABh)
The Release from Power-down / Device ID instruction is a multi-purpose instruction. It can be used to
release the device from the power-down state, or obtain the devices electronic identification (ID) number.
To release the device from the power-down state, the instruction is issued by driving the /CS pin low, shifting
the instruction code “ABh” and driving /CS high as shown in Figure 38a & 38b. Release from power-down
will take the time duration of tRES1 (See AC Characteristics) before the device will resume normal operation
and other instructions are accepted. The /CS pin must remain high during the tRES1 time duration.
When used only to obtain the Device ID while not in the power-down state, the instruction is initiated by
driving the /CS pin low and shifting the instruction code “ABh” followed by 3-dummy bytes. The Device ID
bits are then shifted out on the falling edge of CLK with most significant bit (MSB) first. The Device ID value
for the W25Q32FW is listed in Manufacturer and Device Identification table. The Device ID can be read
continuously. The instruction is completed by driving /CS high.
When used to release the device from the power-down state and obtain the Device ID, the instruction is the
same as previously described, and shown in Figure 38c & 38d, except that after /CS is driven high it must
remain high for a time duration of tRES2 (See AC Characteristics). After this time duration the device will
resume normal operation and other instructions will be accepted. If the Release from Power-down / Device
ID instruction is issued while an Erase, Program or Write cycle is in process (when BUSY equals 1) the
instruction is ignored and will not have any effects on the current cycle.
/CS
CLK
Mode 3
Mode 0
DI
(IO0)
01234567
Instruction (ABh)
tRES1
Mode 3
Mode 0
Power-down current Stand-by current
Figure 38a. Release Power-down Instruction (SPI Mode)
/CS
CLK
IO0
Mode 3
Mode 0
01
Instruction
ABh
IO1
IO2
IO3
tRES1
Mode 3
Mode 0
Power-down current
Stand-by current
- 54 -
Publication Release Date: July 01, 2016
- Revision H
 