datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

EM636165TS-10IG View Datasheet(PDF) - Etron Technology

Part Name
Description
View to exact match
EM636165TS-10IG
Etron
Etron Technology Etron
EM636165TS-10IG Datasheet PDF : 73 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
EtronTech
1M x 16 SDRAM EM636165-XXI
6. A.C. Test Conditions
LVTTL Interface
Reference Level of Output Signals
Output Load
Input Signal Levels
Transition Time (Rise and Fall) of Input Signals
Reference Level of Input Signals
1.4V / 1.4V
Reference to the Under Output Load (B)
2.4V / 0.4V
1ns
1.4V
Output
30pF
3.3V
1.2k
870
Output
Z0= 50
1.4V
50
30pF
LVTTL D.C. Test Load (A)
LVTTL A.C. Test Load (B)
7. Transition times are measured between VIH and VIL. Transition(rise and fall) of input signals are in a fixed
slope (1 ns).
8. tHZ defines the time in which the outputs achieve the open circuit condition and are not at reference
levels.
9. These parameters account for the number of clock cycle and depend on the operating frequency of the
clock as follows:
the number of clock cycles = specified value of timing/Clock cycle time
(count fractions as a whole number)
10.If clock rising time is longer than 1 ns, ( tR / 2 -0.5) ns should be added to the parameter.
11.Assumed input rise and fall time tT ( tR & tF ) = 1 ns
If tR or tF is longer than 1 ns, transient time compensation should be considered, i.e., [(tr + tf)/2 - 1] ns
should be added to the parameter.
12. Power up Sequence
Power up must be performed in the following sequence.
1) Power must be applied to VDD and VDDQ(simultaneously) when all input signals are held "NOP" state
and both CKE = "H" and LDQM/UDQM = "H." The CLK signals must be started at the same time.
2) After power-up, a pause of 200µseconds minimum is required. Then, it is recommended that
LDQM/UDQM is held "HIGH" (VDD levels) to ensure DQ output is in high impedance.
3) Both banks must be precharged.
4) Mode Register Set command must be asserted to initialize the Mode register.
5) A minimum of 2 Auto-Refresh dummy cycles must be required to stabilize the internal circuitry of
the device.
Preliminary
20
Rev. 1.1 Apr. 2005
 

Share Link: 