ADP3806
Parameter1
ISET INPUT
Charge Current Programming Function
Programming Function Accuracy
Symbol
VISET/VCS
ISET Bias Current
BATSEL INPUT
VBAT = 12.6 V
VBAT = 16.8 V
BATSEL Input Current
BOOST REGULATOR OUTPUT
Output Voltage
Output Current8
ANALOG REGULATOR OUTPUT
Output Voltage
Output Current8
PRECISION REFERENCE OUTPUT
Output Voltage
Output Current8
SHUTDOWN (SD)
On
Off
SD Input Current
POWER SUPPLY
On Supply Current
Off Supply Current
UVLO Threshold Voltage
UVLO Hysteresis
LC OUTPUT
Output Voltage Low
Output Voltage High
OUTPUT REVERSE LEAKAGE PROTECTION
Leakage Current
OVERCURRENT COMPARATOR
Overcurrent Threshold
Response Time
OVERVOLTAGE COMPARATOR
Overvoltage Threshold
Response Time
IB
VBSTREG
IBSTREG
VREG
IREG
VREF
IREF
SDH
SDL
ISYON
ISYOFF
VUVLO
IDISCH
VCS(OC)
tOC
VBAT(OV)
tOV
Conditions
0.0 V < VISET ≤ 4.0 V
VISET = 4.0 V, 1 V ≤ VCS(CM) ≤ 16 V
VISET = 0.50 V, 1 V ≤ VCS(CM) ≤ 10 V
5°C ≤ TA ≤ 55°C, VISET = 206 mV,
VCS(CM) = 5 V and 10 V
0.0 V ≤ VISET ≤ 4.0 V
CL = 0.1 μF
CL = 10 nF
No external loads, UVLO ≤ VCC ≤ 20 V
No external loads, VCC ≤ 20 V
Turn on
Turn off
High current mode9, ISINK = 100 μA
Low current mode10
VCC = floating, VBAT = 12.6 V
VCS > 180 mV to COMP < 1 V
VBAT > 120% to COMP < 1 V
Min Typ
Max
25
−5 ±1.0
+5
−30 ±10
+30
−46.7
+33
0.2
1.0
2.0
0.8
0.2
5.0
6.8 7.0
7.2
3.0 5.0
5.8 6.0
6.2
3.0 5.0
2.47 2.5
2.53
0.5 1.1
2.0
0.8
0.2
1.0
6.0
8.0
1.0
5.0
5.65 6.0
6.25
0.1 0.3
0.5
0.1
0.4
External
1
5
180
2
120
2
1 All limits at temperature extremes are guaranteed via correlation using standard statistical quality control (SQC) methods.
2 Guaranteed by design, not tested in production.
3 If SYNC function is used, then fSYNC must be greater than fCT but less than 120% of fCT.
4 VCS = (VCS+) − (VCS−).
5 Accuracy guaranteed by ISET input, programming function accuracy specification.
6 System current sense is active during shutdown.
7 Load current is supplied through SYS+ pin.
8 Guaranteed output current from 0 to minimum specified value to maintain regulation.
9 VBAT < 93% of final or VCS > 25 mV.
10 VBAT ≥ 93% of final or VCS ≤ 25 mV.
Unit
V/V
%
%
%
μA
V
V
μA
V
mA
V
mA
V
mA
V
V
μA
mA
μA
V
V
V
V
μA
mV
μs
%
μs
Rev. C | Page 4 of 16
 