DC-to-DC Step-Down Converter
ELECTRICAL CHARACTERISTICS1, valid at TA = 25°C, VO = 5 V (adjusted), R1 = 4.2 kΩ, R1 = 0.8 kΩ
Characteristic
Symbol
Test Conditions
Min. Typ.
Reference Voltage
VADJ VIN = 15 V, IO = 0.2 A
0.784 0.800
Reference Voltage Temperature Coefficient
Efficiency2
VADJ/T VIN = 15 V, IO = 0.2 A, TC = 0 to 100 °C
η
VIN = 15 V, IO = 2 A
– ±0.1
83
Operating Frequency
fO
VIN = 15 V, IO = 2 A
270 300
Line Regulation
VLine VIN = 10 to 30 V, IO = 2 A
Load Regulation
VLoad VIN = 15 V, IO = 0.2 to 3.5 A
Overcurrent Protection Threshold Current
SS Terminal On/Off Operation Threshold Voltage
IS
VSSL
VIN = 15 V
3.6
SS Terminal On/Off Operation Outflow Current
ISSL
VSSL = 0 V
6
Quiescent Current 1
Iq
VIN = 15 V, IO = 0 A
6
Quiescent Current 2
Iq(off)
1Using circuit shown in Typical Application Circuit diagram.
2Efficiency is calculated as: η(%) = ([VO × IO] × [VIN × IIN]) × 100.
VIN = 15 V, VSS = 0 V
200
Max.
0.816
330
80
50
0.5
30
600
Units
V
mV/°C
%
kHz
mV
mV
A
V
μA
mA
μA
Pin-out Diagram
123 45
Terminal List Table
Name Number
Function
IN
1
Supply voltage
SW
2
Regulated supply output
GND
3
Ground terminal
ADJ
4
Terminal for resistor bridge feedback
The SS terminal is used to enable soft start and to control on/off operation of the IC output,
VO (see figure 2). If neither soft start nor on/off control is used, leave pin open.
To enable soft start, connect a capacitor between SS and ground. To control on/off
operation, connect an NPN bipolar transistor, in a TTL open collector output configuration,
SS
5
between the SS terminal and GND. Turn off is done by decreasing VSSL below its rated
level.
When both soft start and VO on/off are used, a protection measure such as current limiting
is required because, if the capacitance of C3 large, the discharge current of C3 flows
across the transistor for on/off operation. Because a pull-up type resistor is provided inside
the IC, no external voltage can be applied.
System
TTL
SI-8000FFE
SS
5
SI-8000FFE
SS
5
C3
System
TTL
SI-8000FFE
SS
5
C3
(a)
VO on/off
control only
(b)
Soft start
only
(c)
VO on/off and
soft start control
Figure 2. Alternative configurations for SS pin. If neither soft start nor VO on/off is required, the SS pin is left open.
Sanken Electric Co., Ltd.
3
3-6-3 Kitano, Niiza-shi, Saitama-ken
352-8666, Japan
Phone:+81-48-472-1111
http://www.sanken-ele.co.jp
 