±18-Bit ADC with Serial Interface
___________________Digital Interface
Serial data at DIN is sent in 8-bit packets and is shifted
into the internal 8-bit shift register with each rising edge
of SCLK. The data is then latched into either command
input register 0 or command input register 1, as deter-
mined by the LSB of the data sent, and is latched on
the rising edge of CHIP SELECT (CS) Data is clocked
out of the selected output register on each falling edge
of SCLK. D7(MSB) must be the first data bit to be shift-
ed in and is the first bit to be shifted out.
Output data is shifted out at the same time command
data is shifted in. Command data must be clocked in
on the previous 8-bit read-write cycle to receive con-
version data in the present cycle.
Since there is no internal power-on reset, initialize the
MAX132 immediately after power-up to insure correct
operation.
Table 2 defines each bit of five registers: the two com-
mand input registers, output register 0, output register
1, and the status output register.
Command Input Register 0
Register-Set Bits
Data bits D1 and D2 of command register 0 (RS1 and
RS0) determine the data to be read on the data bus.
These bits select which register outputs data to the bus.
Table 3 defines the bit values that determine which reg-
ister is read on the next cycle (Figure 9).
REGISTER
INSTRUCTION
(DATA IN)
CYCLE 1
START,
READ STATUS
CYCLE 2
READ HIGHER
BITS
CYCLE 3
READ LOWER
BITS
CYCLE 4
START,
READ STATUS
OUTPUT DATA
OUTPUT STATUS
REGISTER
(EOC, POLARITY, B2–B0)
REGISTER 1
( B11–B18)
REGISTER 0
( B3–B10)
Figure 9. Instruction and Data Sequencing
Read-Zero Bit
The read-zero bit allows the ADC to calibrate on com-
mand for zero offset. The read-zero bit, when set to 1,
internally shorts the inputs; when a start-conversion
command is given, the zero error is converted. Subtract
the results from the standard external measurement
conversion when the read-zero conversion ends. If the
read-zero bit is set to 0, the converter measures the
voltage between IN Hl and IN LO once a start bit is
given. Take a new zero reading periodically and when-
ever the ambient temperature, the reference voltage, or
the common-mode input voltage are changed.
Table 3. Register Set-Bit Definitions
RS1 RS0
DEFINITIONS
0 0 Selects Register 0; output for data bits B3–B10
0 1 Selects Register 1; output for data bits B11–B18
Selects Register 2; output status for data bits
1 0 B0–B2, polarity, sleep, integrating, EOC, and
collision bit
1 1 Invalid data
Table 2. Register Map of Input and Output Data
REGISTER
DATA BIT
D7
D6
D5
D4
D3
D2
D1
D0
Command Input
Register 0
“1”
Start
Convert
“0”
Returns to
0 at EOC
50Hz
60Hz
Sleep Read Zero Don’t Care
Awake Read VIN Don’t Care
RS0*
RS1*
0
Command Input
Register 1
Set P3
Output
Set P2
Output
Set P1
Output
Set P0
Output
Don’t Care Don’t Care Don’t Care
1
Output Register 0
RS1 = 0, RS0 = 0
B10
B9
B8
B7
B6
B5
B4
B3
Output Register 1
RS1 = 0, RS0 = 1
B18
MSB
B17
B16
B15
B14
B13
B12
B11
Output Status
“1” Collision
EOC
Integrating
Input
Sleep
-Polarity
Register
B2
RS1 = 1, RS0 = 0
“0”
No Collision
Converting
Not
Integrating
Awake
+Polarity
B1
B0
LSB
*Note: Refer to Table 3.
10 ______________________________________________________________________________________
 