datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

74VHCT08PW,118 View Datasheet(PDF) - NXP Semiconductors.

Part Name
Description
View to exact match
74VHCT08PW,118
NXP
NXP Semiconductors. NXP
74VHCT08PW,118 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Nexperia
74VHC08; 74VHCT08
Quad 2-input AND gate
10. Dynamic characteristics
Table 7. Dynamic characteristics
GND = 0 V; For test circuit see Figure 7.
Symbol Parameter Conditions
25 °C
40 °C to +85 °C 40 °C to +125 °C Unit
Min Typ[1] Max Min
Max
Min
Max
For type 74VHC08
tpd
propagation nA, nB to nY; see Figure 6 [2]
delay
VCC = 3.0 V to 3.6 V
CL = 15 pF
- 4.0 8.8 1.0
10.5
1.0
11.0 ns
CL = 50 pF
VCC = 4.5 V to 5.5 V
- 5.6 12.3 1.0
14
1.0
15.5 ns
CL = 15 pF
- 3.0 5.9 1.0
7.0
1.0
7.5 ns
CL = 50 pF
4.2 7.9 1.0
9.0
1.0
10.0 ns
CPD
power
CL = 50 pF; fi = 1 MHz;
[3] - 10.0 -
-
-
-
-
pF
dissipation VI = GND to VCC
capacitance
For type 74VHCT08
tpd
propagation nA, nB to nY; see Figure 6 [2]
delay
VCC = 4.5 V to 5.5 V
CL = 15 pF
- 3.2 6.9 1.0
8.0
1.0
9.0 ns
CL = 50 pF
- 4.2 7.9 1.0
9.0
1.0
10.0 ns
CPD
power
CL = 50 pF; fi = 1 MHz;
[3] - 12.0 -
-
-
-
-
pF
dissipation VI = GND to VCC
capacitance
[1] Typical values are measured at nominal supply voltage (VCC = 3.3 V and VCC = 5.0 V).
[2] tpd is the same as tPLH and tPHL.
[3] CPD is used to determine the dynamic power dissipation (PD in µW).
PD = CPD × VCC2 × fi × N + Σ(CL × VCC2 × fo) where:
fi = input frequency in MHz, fo = output frequency in MHz
CL = output load capacitance in pF
VCC = supply voltage in Volts
N = number of inputs switching
Σ(CL × VCC2 × fo) = sum of the outputs.
74VHC_VHCT08_1
Product data sheet
Rev. 01 — 30 June 2009
© Nexperia B.V. 2017. All rights reserved
6 of 14
 