OUTPUT CHARACTERISTICS
Parameter
Rated Power1
Voltage Set Point Accuracy
Line regulation
Load Regulation
Ripple and Noise
Conditions
TA=-40°C to 85°C
NMH0505DC/SC
All other types
High VIN to low VIN
10% load to rated load, 5V output types
10% load to rated load, 9V output types
10% load to rated load, 12V output types
10% load to rated load, 15V output types
BW=DC to 20MHz, 5V output types
BW=DC to 20MHz, 9V output types
BW=DC to 20MHz, 12V output types
BW=DC to 20MHz, 15V output types
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NMH05 types
Input voltage VIN, NMH12 types
Input voltage VIN, NMH24 types
Input voltage VIN, NMH48 types
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Flash tested for 1 second
Resistance
Viso= 500V
GENERAL CHARACTERISTICS
Parameter
Conditions
5V input types
Switching frequency
12V input types
24V & 48V input types
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Specification
All output types
Storage
5V output types
Case Temperature above ambient
12V output types
Cooling
Free air convection
TEMPERATURE DERATING GRAPH
3
2
85°C
1 Safe Operating Area
0
-40 0 50 100 150
Ambient Temperature (°C)
1. See derating graph.
www.murata-ps.com/support
NMH Series
Isolated 2W Dual Output DC/DC Converters
Min.
Typ.
Max.
Units
2
W
-5
7.5
%
-5
5
1.0
1.2
%/%
5
10
%
3
10
150
200
100
150
mV p-p
80
150
70
150
300°C
300mW
7V
15V
28V
54V
Min.
Typ.
Max.
Units
1000
VDC
1
10
Min.
Typ.
Max.
Units
95
90
kHz
80
Min.
Typ.
Max.
Units
-40
85
-50
130
°C
30
25
TOLERANCE ENVELOPE
+10%
+5%
VNOM
Typical Load Line
+2.5%
-2.5%
-7.5%
10 25
50
75 100
Output Load Current (%)
The voltage tolerance envelope shows typical load regulation characteristics for this
product series. The tolerance envelope is the maximum output voltage variation due
to changes in output loading.
KDC_NMH.F01 Page 2 of 6
 