G9SX-LM
Wiring of Inputs and Outputs
Signal Name
Power supply
input
Enabling input
ch1
Enabling input
ch2
Terminal
Name
A1, A2
T11, T12
T21, T22
Description of operation
Wiring
The input terminals for power supply.
Connect the power source to the A1 and A2 terminals.
Connect the power supply plus (24 VDC) to the A1 terminal.
Connect the power supply minus (GND) to the A2 terminal.
Using 1 safety
Enabling
Switch
+24V
+24V
input channel
T11 T12 T21 T22
Y1
To set Safety instantaneous outputs in the ON state in the
Maintenance mode, HIGH state signals must be input to Using 2 safety Enabling
+24V
+24V
both of enabling input CH1 and enabling input CH2. input channels Switch
+24V
Otherwise Safety instantaneous outputs cannot be in the (cross fault
ON state.
detection OFF)
T11 T12 T21 T22
Y1
Using 2 safety
Enabling
Switch
input channels
(cross fault
NC
detection ON)
T11 T12 T21 T22
Y1
+24V
Safety input
ch1
T61, T62
Safety input
ch2
T71, T72
Reset/Feedback T31, T32,
Input
T33
Logical AND
connection
input
T41, T42
Using 1 safety
input channel
To set Safety instantaneous outputs in ON state in the
Normal operating mode, HIGH state signals must be input Using 2 safety
to both of Safety input CH1 and Safety input CH2 input channels
Otherwise Safety instantaneous outputs cannot be in ON (cross fault
state.
detection OFF)
+24V
T61 T62 T71 T72
Y2
+24V
+24V
T61 T62 T71 T72
+24V
Y2
Using 2 safety
input channels
(cross fault
detection ON)
NC
T61 T62 T71 T72
Y2
To set Safety instantaneous outputs in the ON state, the
ON state signal must be input to T33. Otherwise Safety Auto reset
instantaneous outputs cannot be in the ON state.
+24V
Feedback loop
KM
T31 T32 T33
To set Safety instantaneous outputs in the ON state, the signal
input to T32 must change from the OFF state to the ON state,
and then to the OFF state. Otherwise Safety instantaneous
Manual reset
outputs cannot be in the ON state.
Feedback loop
+24V
KM
T31 T32 T33
The logical AND connection means that lower unit (Unit B)
calculates the logical multiplication (AND) of the safety
output information from upper unit(Unit A) and safety input
signal "b", which is input to lower unit. In the example of a
right picture, the safety output of Unit C is "a" AND "b" .
Connect L1 or L2 of upper unit to T41 of lower unit, and
connect GND of upper unit to T42 of lower unit. To set
Safety instantaneous outputs of the subsequent Unit in ON
state, its Logical AND Connection Preset Switch must be
set to AND (enabled) and High state signal must be input
to T41 of the subsequent unit.
Unit A
input 1
G9SX-LM
L1
output
A2
Next unit (4 unit Max.)
Logical AND connection sig. (1st layer)
Unit B T41
input 2
T42
T41 T42
G9SX-LM
G9SX-LM
L1
output
A2
Logical AND connection sig. (2nd layer)
T41 T42
G9SX-LM
L1
A2
Next unit (4 unit Max.)