datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

108296138 View Datasheet(PDF) - Agere -> LSI Corporation

Part Name
Description
View to exact match
108296138 Datasheet PDF : 112 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Ambassador T8100A, T8102, and T8105
H.100/H.110 Interfaces and Time-Slot Interchangers
Advance Data Sheet
November 1999
2 Architecture and Functional Description (continued)
2.1 Register/Memory Maps (continued)
2.1.3 Address Mode Register
The AMR is defined in Table 10 below where (aaaa) is the stream address and the LAR is the time-slot address of
the selected memory space.
Note: All unused AMR values are reserved.
Table 10. Address Mode Register
Bits Bits
7—4 3—0
Register Function
0000 0000 Control Registers.
0001 (aaaa) Local Bus, Data Memory 1.
0010
0100
0101
0111
1001
1001
1010
1010
1011
1011
(aaaa)
(aaaa)
(aaaa)
0000
0000
0001
0000
0001
0000
0001
Local Bus, Data Memory 2.
Local Bus, Connection Memory, Time-Slot Field.
Local Bus, Connection Memory, Stream, and Control Bit Field.
Local Bus, Holding Registers, Reset.
CAM, Data Memory 1. Lower 256 Addresses.
CAM, Data Memory 1. Upper 256 Addresses (T8102, T8105 only).
CAM, Data Memory 2. Lower 256 Addresses.
CAM, Data Memory 2. Upper 256 Addresses (T8102, T8105 only).
CAM, Connection, Time-Slot Field.
CAM, Connection, Stream, and Control Bit Field.
1011
1011
1110
1110
0010
0011
0000
0001
CAM, Connection, Tag Field.
CAM, Connection, Subrate Control, Tag Field MSB.
CAM, Even, Make Connection (MKCE). Write to Next Free Location.
CAM, Odd, Make Connection (MKCO). Write to Next Free Location.
1110
1110
1110
1110
0011
0100
0101
0111
CAM, Local, Make Connection (MKCL). Write to Next Free Location.
CAM, Even, Break Connection (BKCE).
CAM, Odd, Break Connection (BKCO).
CAM, Local, Break Connection (BKCL).
1110
1100
1110
1100
1110
1100
1110
1100
1110
1100
1110
1100
1111
1111
1111
1000
1000
1001
1001
1011
1011
1100
1100
1101
1101
1111
1111
0000
0001
0011
CAM, Even, Clear Location (CLLE). Lower 256 Range. Requires LAR.
CAM, Even, Clear Location (CLLE). Upper 256 Range. Requires LAR (T8102, T8105 only).
CAM, Odd, Clear Location (CLLO). Lower 256 Range. Requires LAR.
CAM, Odd, Clear Location (CLLO). Upper 256 Range. Requires LAR (T8102, T8105 only).
CAM, Local, Clear Location (CLLL). Lower 256 Range. Requires LAR.
CAM, Local, Clear Location (CLLL). Upper 256 Range. Requires LAR (T8102, T8105 only).
CAM, Even, Read Location (RDCE). Lower 256 Range. Requires LAR, IDR Holds Results.
CAM, Even, Read Location (RDCE). Upper 256 Range. Requires LAR, IDR Holds Results (T8102, T8105 only).
CAM, Odd, Read Location (RDCO). Lower 256 Range. Requires LAR, IDR Holds Results.
CAM, Odd, Read Location (RDCO). Upper 256 Range. Requires LAR, IDR Holds Results (T8102, T8105 only).
CAM, Local, Read Location (RDCL). Lower 256 Range. Requires LAR, IDR Holds Results.
CAM, Local, Read Location (RDCL). Upper 256 Range. Requires LAR, IDR Holds Results (T8102, T8105 only).
CAM, Even, Find Entry (FENE). IDR Holds Results.
CAM, Odd, Find Entry (FENO). IDR Holds Results.
CAM, Local, Find Entry (FENL). IDR Holds Results.
1111
1111
1111
1111
1111
1000
1001
1011
1100
1111
CAM, Even, Reset (RSCE).
CAM, Odd, Reset (RSCO).
CAM, Local, Reset (RSCL).
CAM, Holding Registers, Reset (RCH).
CAM, Initialize (CI). Reset All CAM Locations and Holding Registers.
16
Lucent Technologies Inc.
 

Share Link: 