datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

AGQ20006 View Datasheet(PDF) - Panasonic Corporation

Part Name
Description
View to exact match
AGQ20006 Datasheet PDF : 5 Pages
1 2 3 4 5
GQ (AGQ)
3) High sensitivity single side stable type
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
6V DC
9V DC
12V DC
Set voltage
(at 20°C 68°F)
80%V or less of
nominal voltage*
(Initial)
Reset voltage
(at 20°C 68°F)
10%V or more of
nominal voltage*
(Initial)
24V DC
*Pulse drive (JIS C 5442-1996)
Nominal operating
current
[±10%] (at 20°C 68°F)
66.7mA
33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
5.0mA
Coil resistance
[±10%] (at 20°C 68°F)
22.5
90
202.5
360
810
1,440
4,800
Nominal operating
power
100mW
120mW
Max. applied voltage
(at 20°C 68°F)
150%V of
nominal voltage
120%V of
nominal voltage
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Single side stable
Nominal operating High sensitivity single side
power
stable type
1 coil latching
Insulation resistance (Initial)
Electrical
characteristics
Breakdown voltage
(Initial)
Surge breakdown
voltage (Initial)
Between open contacts
Between contact and coil
Between contact sets
Between open contacts
Between contacts and coil
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Mechanical
characteristics
Expected life
Shock resistance
Vibration resistance
Mechanical
Functional
Destructive
Functional
Destructive
Electrical
Conditions
Unit weight
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Specifications
2 Form C
Max. 100 m(By voltage drop 6 V DC 1A)
Stationary contact: AgPd+Au clad Movable contact: AgPd
2 A 30 V DC, 1 A 30 V DC, 0.3 A 125 V AC (resistive load)
60 W (DC), 30 W (DC), 37.5 V A (AC) (resistive load)
110 V DC, 125 V AC
2A
10µA 10 mV DC
140mW (1.5 to 12 V DC), 230mW (24 V DC)
100mW (1.5 to 12 V DC), 120mW (24 V DC)
Min. 1,000M(at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 5 × 107 (at 180 cpm)
Min. 5 × 104 (2 A 30 V DC resistive), Min. 105 (1 A 30 V DC resistive),
Min. 105 (0.3 A 125 V AC resistive) (at 20 cpm)
Ambient temperature:
(Single side stable, 1 coil latching type) –40°C to +85°C –40°F to +185°F
(High sensitivity single side stable type) –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 1 g .035 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
REFERENCE DATA
1. Max. switching capacity
* Max. switching capacity is 2A 30V DC.
2. Life curve
100
3. Mechanical life
Tested sample: AGQ200A4H, 6 pcs.
Operating speed: 180 cpm
DC resistive load
4
AC resistive load
1.0
50
40
Pick-up voltage
Max.
3
30
Min.
DC 30V resistive load
20
2
0.3
10
AC 125V
resistive load
Drop-out voltage
1
Max.
Min.
30
100
Contact voltage, V
0
0.2 0.4 0.6 0.8 1.0 1.2
Switching current, A
0
0
10
30
50
No. of operations, ×104
ASCTB7E 201209-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
 

Share Link: 