datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

MC-4516CB647XFA-A75 View Datasheet(PDF) - Elpida Memory, Inc

Part Name
Description
View to exact match
MC-4516CB647XFA-A75 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-4516CB647XFA
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
Operating current
ICC1 Burst length = 1
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 2
/CAS latency = 3
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC2PS CKE VIL(MAX.), tCK =
Precharge standby current in
non power down mode
ICC2N
CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during
30 ns.
ICC2NS CKE VIH(MIN.), tCK = Input
signals are stable.
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
power down mode
ICC3PS CKE VIL(MAX.), tCK =
Active standby current in non
power down mode
ICC3N
CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during
30 ns.
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
Operating current
ICC4 tCK tCK(MIN.)
/CAS latency = 2
(Burst mode)
IO = 0 mA
/CAS latency = 3
CBR (Auto) refresh current
ICC5 tRC tRC(MIN.)
/CAS latency = 2
/CAS latency = 3
Self refresh current
ICC6 CKE 0.2 V
Input leakage current
Output leakage current
II(L) VI = 0 to 3.6 V, All other pins not under
test = 0 V
IO(L) DOUT is disabled, VO = 0 to 3.6 V
High level output voltage
VOH IO = – 4.0 mA
Low level output voltage
VOL IO = + 4.0 mA
-A75
MIN.
MAX.
800
840
8
8
160
64
40
32
240
–8
– 1.5
2.4
160
960
1,240
1,840
1,920
16
+8
+ 1.5
0.4
Unit Notes
mA
1
mA
mA
mA
mA
mA
mA
2
mA
3
mA
µA
µA
V
V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet E0232N20 (Ver. 2.0)
 