GASTUBE
ARRESTER
Gas tube arrester(GTA)is a surge absorber
featuring low capacitance and high surge
absorption energy.
lt consists of a sealed tube in which inert
gas is injected and electrodes which are
set at fixed intervals. The simple structure
and the dimensional accuracy offer high
reliability and stabilized characteristics.
Applications
1. Protection for telephone set, facsimile, telex,
telephone system, CATV, computer and peripheral
equipment.
2. Semiconductor circuit protection in equipment
that also uses high voltage such as TV,
oscilloscope, and electron microscope.
3. Automatic control of luminous energy in
stroboscopic tube.
4. Generator of high-voltage for gas igniter.
Voltage-Current Characteristics
The current through the GTA is changed over the
range of values of 10Ϫ18 to 102 amps which is shown
as the figure below and the voltage across the GTA will
also valy.The discharge characteristics are changed to
various mode by the flowing current, and the final
mode of the discharge characteristics is arc discharge .
Non self
sustaining
Townsent
b
c
Glow
f
abnomalous
glow
Maximum Single lmpulse Dischrge Current
This test is to determine the ability o f the GTA t o
conduct a maximum single impulse Discharge
current. The current impulse waveform is 8 / 20s.
The maximum single impulse discharge current
is the crest current of the impulse.
Capacitance
The capacitance of the GTA is defined as
capacitance across terminals of the GTA at 1 kHz.
Operating Temperature Range
Ϫ20ЊCϳ65ЊC
DC Holdover Voltage
This values is defined as the maximum DC voltage
across the terminals of the GTA which is expected
to clear and restore its high impedance state within
150 ms or less after the passage of a surge.
loc
Ro
ϩ
1
V
Ϫ
D
R
C
li
D
ϩ
2V
T
Ϫ
a 10Ϫ16A
d
e
10Ϫ4ϳ10Ϫ5A
Current
Arc
g
1A
1. DC constant-voltage regulated power supply
2. lmpulse generator
Ro : DC current adjustment resistor
R : Line mimic resistor 136 Ohms
C : Line mimic capacitor 0.083F
D : lnsulation diode
When the applied voltage across the GTA exceeds
the breakdown voltage (sparkover voltage), the
current through the GTA increases rapidly to value
of several amps or greater. The rate of current rise and
level to be reached are limited by the series impedance
of the circuit.The voltage across the GTA at this
time is very low with typical value of 20 to 30 volts.
Electrical Characteristics
AC Discharge Current
The current is the rms value of sinusoidal alternating
current of 50Hz or 60Hz which can flow through the
GTA in accordance with a certain test method without
substantially altering its sparkover voltage. The
usual test consists of specified loads applied for 1
sec at interval of 1 min alternately. ln the test of the
maximum AC discharge current, the GTA is applied
9 cycles of 50Hz AC(180 ms) continuously.
lmpulse Surge Life
The life is defined as the minimum number of surges
of a certain current waveform the GTA can survive
without deterioration of its operating specifications.
lnsulation Resistance
This is defined as the resistance value across the
terminal of GTA at 100VDC for devices over 230VDC
(140VDC for GTA type) breakdown voltage and 50VDC
for devices less than 230VDC(140VDC for GTA type) ratings.
DC Breakdown Voltage
The voltage is the minimum slowly rising DC voltage that
will cause sparkover when applied across the terminal
of the GTA.The GTA shall be placed in darkness for
at least 15 min and tested in this condition using a
ramp voltage waveform with 100V/s to 500V/s.
The GTA shall be tested with a positive and a
negative waveform. The sparkover current for DC
sparkover voltage test shall be within 10 amps.
Impulse Breakdown Voltage
The GTA to be exposed to the test shall be kept in
total darkness before (for at least 15 min) and during
the test. Then, with a ramp voltage with 5kV /s
applied to the GTA, the breakdown voltage level is
recorded. ln case of testing with opposite polarity,
using the same GTA, a minimum of 15 min shall
elapse.
Impulse Waveform
lmpulse breakdown voltage is the voltage at which
the GTA fires when the voltage increases at rates
of more than 100V/s. This value may not vary even
after the GTA has been stored in the dark for long
period. The value of the impulse breakdown voltage
increases with increasing steepness of the surge
voltage as the figure below.
100
90
50
10
Tf
Tt
Time (s)
40
Direct download click here
 

NON-CONTACT SENSOR      4 page
  THERMOPILE
  NC SENSOR

THERMISTOR                                          6
   HIGH PRECISION SERIES
   SMD SERIES
  HIGH HEAT-RESISTANCE SERIES
  DISK SERIES
  SENSORS

POWER THERMISTOR              21page
   D-TYPE SERIES
   MARK SERIES
   D2-TYPE SERIES

VRD (TRANSIENT VOLTAGE SUPPRESSOR)    26page
   SMD SERIES
   LEAD TYPE SERIES

CRD (CURRENT REGULATIVE DIODE)           30page
  LEAD TYPE SERIES
  MELF TYPE SERIES

ZENAMIC (METAL OXIDE VARISTOR)          32page
  LEAD TYPE SERIES
  M TYPE SERIES
  SURGE ABSORBER UNIT SERIES

GAS TUBE ARRESTER                               page40
   CERAMIC TUBE SERIES
   GLASS TUBE SERIES
   SA-01 SERIES

Share Link : Semitec
All Rights Reserved © datasheetbank.com 2014 - 2018 [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]