LF
VDE
20A Power Relay For
Home appliances
LF-RELAYS
30.1
1.185
15.7
.618
23.3
.917
TMP type
FEATURES
30.1
15.7
.618
1. Ideal for compressor and inverter
1.185
loads
23.3 1) Compressor load: 20A 250V AC
.917 2) Inverter load: 20A 100V AC, 10A 200V AC
2. High insulation resistance
• Creepage distance and clearances
between contact and coil;
PCB type
Creepage Min. 9.5mm .374inch/Clear-
mm inch ance Min. 8mm .315inch
• Surge withstand voltage: Min. 10,000V
3. "PCB" and "TMP" types available
4. Conforms to the various safety
standards:
UL/CSA, TÜV, VDE approved
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching
capacity
Rating
(resistive load)
Max. switching
power
Max. switching
voltage
Max. switching
current
Expected life
(min. operations)
Mechanical
(at 180 cpm)
Electrical
(at 20 cpm)
(Resistive load)
1 Form A
100 m
Silver alloy
20 A 250V AC
6,250 V A
250V AC
25 A
2 × 106
105
Coil
Nominal operating power
900 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 Detection current: 10mA
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time.
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*6 Half-wave pulse of sine wave: 6 ms
*7 Detection time: 10 µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Characteristics
Max. operating speed
(at rated load)
Initial insulation resistance*1
Initial breakdown
voltage* 2
Between open
contacts
Between contacts
and coil
Surge voltage between contact and
coil* 3
Operate time*4
(at nominal voltage)
Release time (without diode)*4
(at nominal voltage)
Temperature rise
(at nominal voltage)
Shock
resistance
Functional* 5
Destructive*6
Vibration
resistance
Functional* 7
Destructive
Conditions for
operation, trans-
Ambient temp.
port and storage*8
(Not freezing and
condensing at low Humidity
temperature)
Unit weight
20 cpm
Min. 1,000 M(at 500 V DC)
1,000 Vrms for 1 min.
5,000 Vrms for 1 min.
Min. 10,000 V
Approx. 15ms
Approx. 15ms
Max. 45°C
(resistance method, contact
current 20 A, rated coil
voltage, 60°C 140°F)
Min. 100 m/s2{10 G}
Min. 1,000 m/s2{100 G}
10 to 55Hz
at double amplitude of 1.5mm
10 to 55Hz
at double amplitude of 1.5mm
–40°C to +60°C
–40°F to +140°F
5 to 85% R.H.
Approx. 23 g .81 oz
TYPICAL
APPLICATIONS
• Air conditioner
• Refrigerators
• OA equipment
40
ORDERING INFORMATION
Ex. A LF 1 T 12
Product Name
LF
Contact arrangement
1: 1 Form A
Terminal shape
T: TMP type
P: PCB type
Note: Standard packing; Carton: 50 pcs. Case 200 pcs.
UL/CSA,VDE, TÜV approved type is standard.
Coil voltage, V DC
05: 5
06: 6
09: 9
12: 12
18: 18
24: 24
 