1N5333B through 1N5388B
ELECTRICAL CHARACTERISTICS — continued (TA = 25°C unless otherwise noted, VF = 1.2 Max @ IF = 1 A for all types)
JEDEC
Type No.
(Note 1)
Nominal
Zener
Voltage
VZ @ IZT
Volts
(Note 2)
Test
Current
IZT
mA
Max Zener Impedance
Max Reverse
Leakage Current
ZZT @IZT ZZK @ IZK = 1 mA
Ohms
Ohms
(Note 2)
(Note 2)
IR @ VR
µA
Volts
Max
Surge
Current
ir, Amps
(Note 3)
Max Voltage
Regulation
VZ, Volt
(Note 4)
Maximum
Regulator
Current
IZM
mA
(Note 5)
1N5383B
150
8
330
1N5384B
160
8
350
1N5385B
170
8
380
1N5386B
180
5
430
1N5387B
190
5
450
1N5388B
200
5
480
1500
1650
1750
1750
1850
1850
0.5
114
1.1
0.5
122
1.1
0.5
129
1
0.5
137
1
0.5
144
0.9
0.5
152
0.9
3
31.6
3
29.4
3
28
4
26.4
5
25
5
23.6
NOTE 1. TOLERANCE AND TYPE NUMBER DESIGNATION
The JEDEC type numbers shown indicate a tolerance of ±5%.
NOTE 2. ZENER VOLTAGE (VZ) AND IMPEDANCE (ZZT & ZZK)
Test conditions for zener voltage and impedance are as follows: IZ is applied 40 ± 10 ms prior
to reading. Mounting contacts are located 3/8to 1/2from the inside edge of mounting clips
to the body of the diode. (TA = 25°C +8, –2°C).
NOTE 3. SURGE CURRENT (ir)
Surge current is specified as the maximum allowable peak, non-recurrent square-wave cur-
rent with a pulse width, PW, of 8.3 ms. The data given in Figure 6 may be used to find the
maximum surge current for a square wave of any pulse width between 1ms and 1000 ms by
plotting the applicable points on logarithmic paper. Examples of this, using the 3.3 V and
200 V zeners, are shown in Figure 7. Mounting contact located as specified in Note 3. (TA =
25°C +8, –2°C.)
NOTE 4. VOLTAGE REGULATION (VZ)
Test conditions for voltage regulation are as follows: VZ measurements are made at 10% and
then at 50% of the IZ max value listed in the electrical characteristics table. The test current
time duration for each VZ measurement is 40 ± 10 ms. (TA = 25°C +8, –2°C). Mounting contact
located as specified in Note 2.
NOTE 5. MAXIMUM REGULATOR CURRENT (IZM)
The maximum current shown is based on the maximum voltage of a 5% type unit, therefore,
it applies only to the B-suffix device. The actual IZM for any device may not exceed the value
of 5 watts divided by the actual VZ of the device. TL = 75°C at 3/8maximum from the device
body.
NOTE 6. SPECIALS AVAILABLE INCLUDE:
Nominal zener voltages between the voltages shown and tighter voltage tolerance such as
±1% and ±2%. Consult factory.
TEMPERATURE COEFFICIENTS
10
8
6
4
2
RANGE
0
–2
3
4
5
6
7
8
9
10
VZ, ZENER VOLTAGE @ IZT (VOLTS)
Figure 2. Temperature Coefficient-Range
for Units 3 to 10 Volts
300
200
100
RANGE
50
30
20
10
5
0 20 40 60 80 100 120 140 160 180 200 220
VZ, ZENER VOLTAGE @ IZT (VOLTS)
Figure 3. Temperature Coefficient-Range
for Units 10 to 220 Volts
Devices listed in bold, italic are Motorola preferred devices.
Motorola TVS/Zener Device Data
5 Watt Surmetic 40 Data Sheet
6-135
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]