OAA160
PERFORMANCE DATA*
OAA160
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25ºC)
IF = 10mADC
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
OAA160
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25ºC)
(Load Current = 50mADC)
25
20
15
10
5
0
1.625 2.075 2.525 2.975 3.425 3.875
LED Current (mA)
OAA160
Typical Turn-Off Time
(N=50 Ambient Temperature = 25ºC)
(Load Current = 50mADC; IF = 10mADC)
25
20
15
10
5
0
0.012 0.017 0.022 0.027 0.032 0.037
Turn-Off (ms)
OAA160
Typical Blocking Voltage vs. Temperature
400
395
390
385
380
375
370
365
-40 -20
0 20 40 60
Temperature (ºC)
80 100
OAA160
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25ºC)
(Load Current = 50mADC; IF = 10mADC)
35
30
25
20
15
10
5
0
42.5 43.5 44.5 45.5 46.5 47.5
On-Resistance ()
OAA160
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25ºC)
(Load Current = 50mADC)
25
20
15
10
5
0
1.625
2.075 2.525 2.975 3.425
LED Current (mA)
3.875
OAA160
Typical Load Current vs. Temperature
100
90
80
70
60
50
IF=30mA
40
IF=20mA
30
IF=10mA
20
10
0
-40 -20 0 20 40 60 80 100 120
Temperature (ºC)
OAA160
Typical Turn-On vs. Temperature
1.50
(Load Current = 50mADC)
1.25
1.00
0.75
0.50
0.25
0
-40 -20
IF=10mA
0 20 40 60
Temperature (ºC)
IF=20mA
80 100
OAA160
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
367.5 374.5 381.5 388.5 395.5 402.5
Blocking Voltage (V)
OAA160
Typical Turn-On Time
(N=50 Ambient Temperature = 25ºC)
(Load Current = 50mADC; IF = 10mADC)
30
25
20
15
10
5
0
0.05 0.07 0.09 0.11 0.13 0.15
Turn-On (ms)
OAA160
Typical Leakage vs. Temperature
(Measured across Pins 5 & 6 or 7 & 8)
0.014
0.012
0.010
0.008
0.006
0.004
0.002
0
-40 -20
0 20 40 60
Temperature (°C)
80 100
0.050
OAA160
Typical Turn-Off vs. Temperature
(Load Current = 50mADC)
0.045
0.040
0.035
0.030
0.025
0.020
0.015
0.010
0.005
IF=10mA
0
-40 -20 0
20 40 60
80 100
Temperature (ºC)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our
application department.