74LCX02
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
VCC Supply Voltage (note 1)
VI
Input Voltage
VO
Output Voltage (VCC = 0V)
VO
Output Voltage (High or Low State)
IOH, IOL High or Low Level Output Current (VCC = 3.0 to 3.6V)
IOH, IOL High or Low Level Output Current (VCC = 2.7V)
Top
Operating Temperature
dt/dv Input Rise and Fall Time (note 2)
1) Truth Table guaranteed: 1.5V to 3.6V
2) VIN from 0.8V to 2V at VCC = 3.0V
DC SPECIFICATIONS
Value
2.0 to 3.6
0 to 5.5
0 to 5.5
0 to VCC
± 24
± 12
-55 to 125
0 to 10
Symbol
VIH
VIL
VOH
VOL
II
Ioff
ICC
ICC
Parameter
High Level Input
Voltage
Low Level Input
Voltage
High Level Output
Voltage
Low Level Output
Voltage
Input Leakage
Current
Power Off Leakage
Current
Quiescent Supply
Current
ICC incr. per Input
Test Condition
VCC
(V)
Value
-40 to 85 °C
-55 to 125 °C
Min. Max. Min. Max.
2.7 to 3.6
2.7 to 3.6
2.7
3.0
2.7 to 3.6
2.7
3.0
2.7 to 3.6
IO=-100 µA
IO=-12 mA
IO=-18 mA
IO=-24 mA
IO=100 µA
IO=12 mA
IO=16 mA
IO=24 mA
VI = 0 to 5.5V
2.0
2.0
0.8
0.8
VCC-0.2
2.2
2.4
2.2
0.2
0.4
0.4
0.55
VCC-0.2
2.2
2.4
2.2
0.2
0.4
0.4
0.55
±5
±5
0
VI or VO = 5.5V
2.7 to 3.6 VI = VCC or GND
VI or VO= 3.6 to 5.5V
2.7 to 3.6 VIH = VCC - 0.6V
10
10
± 10
500
10
10
± 10
500
Unit
V
V
V
V
mA
mA
°C
ns/V
Unit
V
V
V
V
µA
µA
µA
µA
DYNAMIC SWITCHING CHARACTERISTICS
Test Condition
Value
Symbol
Parameter
VCC
(V)
TA = 25 °C
Unit
Min. Typ. Max.
VOLP
VOLV
Dynamic Low Level Quiet
Output (note 1)
3.3
CL = 50pF
VIL = 0V, VIH = 3.3V
0.8
-0.8
V
1) Number of outputs defined as "n". Measured with "n-1" outputs switching from HIGH to LOW or LOW to HIGH. The remaining output is
measured in the LOW state.