TLP351
Switching Characteristics (Ta = −40 to 100°C, unless otherwise specified)
Characteristics
Symbol
Test
Circuit
Test Condition
Min Typ.* Max Unit
L→H
tpLH
Propagation delay time
H→L
tpHL
VCC = 30 V
Rg = 47 Ω
Cg = 3 nF
IF = 0 → 5 mA 100
IF = 5 → 0 mA 100
⎯
700
ns
⎯
700
Propagation delay difference
between any two parts or channels
PDD
|tpHL-tpLH|
7
VCC = 30 V, Rg = 47 Ω,
Cg = 3 nF
−500
⎯
500 ns
Output rise time (10-90%)
Output fall time (90-10%)
tr
VCC = 30 V
IF = 0 → 5 mA ⎯
50
⎯
Rg = 47 Ω
ns
tf
Cg = 3 nF
IF = 5 → 0 mA
⎯
50
⎯
Common mode transient immunity
at high level output
Common mode transient immunity
at low level output
CMH
CML
IF = 5 mA
VCM = 1000 Vp-p VO (min) = 26 V
−10000
⎯
8 Ta = 25°C
VCC = 30 V
IF = 0 mA
VO (max) = 1 V
10000
⎯
⎯
V/μs
⎯
*: All typical values are at Ta = 25°C
Test Circuit 1: IOPH
1
IF
4
Test Circuit 3: VOH
1
IF
4
Test Circuit 5: ICCH
1
IF
4
8
V8-6
A IOPH
VCC
5
8 VOH
V
5
VCC
8 ICCH
A
Test Circuit 2: IOPL
1
4
Test Circuit 4: VOL
1
VF
4
Test Circuit 6: ICCL
1
VCC
4
5
8
IOPL
A
VCC
V6-5
5
8
VOL
V
5
VCC
8 ICCL
A
VCC
5
4