TL062, TL062A, TL062B
Absolute maximum ratings and operating conditions
2
Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol
Parameter
VCC Supply voltage(1)
Vi
Input voltage(2)
Vid Differential input voltage(3)
Ptot Power dissipation
Output short-circuit duration(4)
Tstg
Rthja
Rthjc
ESD
Storage temperature range
Thermal resistance junction-to-ambient(5),(6)
SO-8
DIP8
Thermal resistance junction-to-case(5),(6)
SO-8
DIP8
HBM: human body model(7)
MM: machine model(8)
CDM: charged device model(9)
Value
±18
±15
±30
680
Infinite
125
85
40
41
900
150
1.5
Unit
V
V
V
mW
°C
°C/W
°C/W
V
V
kV
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the
supply voltages where the zero reference level is the midpoint between VCC+ and VCC-.
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts,
whichever is less.
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
4. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be
limited to ensure that the dissipation rating is not exceeded.
5. Short-circuits can cause excessive heating and destructive dissipation.
6. Rth are typical values.
7. Human body model: 100 pF discharged through a 1.5 kΩ resistor between two pins of the device, done for
all couples of pin combinations with other pins floating.
8. Machine model: a 200 pF capacitor is charged to the specified voltage, then discharged directly between
two pins of the device with no external series resistor (internal resistor < 5 Ω), done for all couples of pin
combinations with other pins floating.
9. Charged device model: all pins plus package are charged together to the specified voltage and then
discharged directly to ground.
Table 2. Operating conditions
Symbol
Parameter
TL062I, AI, BI TL062C, AC, BC Unit
VCC
Toper
Supply voltage range
Operating free air temperature range
6 to 36
V
-40 to +105
0 to +70
°C