datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

TISP7125F3 View Datasheet(PDF) - Power Innovations Ltd

Part Name
Description
View to exact match
TISP7125F3 Datasheet PDF : 25 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
TISP7125F3, TISP7150F3, TISP7180F3, TISP7240F3, TISP7260F3,
TISP7290F3, TISP7320F3, TISP7350F3, TISP7380F3
TRIPLE BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
MARCH 1994 - REVISED MARCH 2000
THERMAL INFORMATION
Non-repetitive peak on-state pulse derated values for 0 °C TA 70 °C
RATING
Non-repetitive peak on-state pulse current, 0 °C < TA < 70 °C (see Notes 5, 6 and 7)
1/2 (Gas tube differential transient, 1/2 voltage wave shape)
2/10 (Telcordia GR-1089-CORE, 2/10 voltage wave shape)
1/20 (ITU-T K.22, 1.2/50 voltage wave shape, 25 resistor)
8/20 (IEC 61000-4-5, combination wave generator, 1.2/50 voltage wave shape)
10/160 (FCC Part 68, 10/160 voltage wave shape)
4/250 (ITU-T K.20/21, 10/700 voltage wave shape, dual)
0.2/310 (CNET I 31-24, 0.5/700 voltage wave shape)
5/310 (ITU-T K.20/21, 10/700 voltage wave shape, single)
5/320 (FCC Part 68, 9/720 voltage wave shape)
10/560 (FCC Part 68, 10/560 voltage wave shape)
10/1000 (Telcordia GR-1089-CORE, 10/1000 voltage wave shape)
SYMBOL
IPPSM
VALUE
320
175
90
150
90
70
65
65
65
45
40
UNIT
A
NOTES: 5. Initially the TISP® must be in thermal equilibrium at the specified TA. The impulse may be repeated after the TISP® returns to its
initial conditions. The rated current values may be applied either to the R to G or to the T to G or to the T to R terminals.
Additionally, both R to G and T to G may have their rated current values applied simultaneously (In this case the total G terminal
current will be twice the above rated current values).
6. See Applications Information for details on wave shapes.
7. Above 70 °C, derate IPPSM linearly to zero at 150 °C lead temperature.