OFFSET
150mV
140mV
130mV
120mV
110mV
100mV
90mV
80mV
70mV
60mV
50mV
40mV
30mV
20mV
10mV
0mV
-10mV
-20mV
-30mV
-40mV
-50mV
-60mV
-70mV
-80mV
-90mV
-100mV
-110mV
-120mV
-130mV
-140mV
-150mV
Tripath Technology, Inc. - Technical Information
Ry
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
20kΩ
Rx (1%)
13.3kΩ
13.7kΩ
14.3kΩ
14.7kΩ
15.4kΩ
15.8kΩ
16.2kΩ
16.9kΩ
17.4kΩ
17.8kΩ
18.7kΩ
19.1kΩ
19.6kΩ
20.5kΩ
21kΩ
21.5kΩ
22.6kΩ
23.2kΩ
24.3kΩ
24.9kΩ
25.5kΩ
26.7kΩ
27.4kΩ
28.0kΩ
29.4kΩ
30.1kΩ
31.6kΩ
32.4kΩ
33.2kΩ
34.8kΩ
35.7kΩ
3) A DC servo using a dual op amp can also be used to automatically null any offset voltage.
This DC servo will only eliminate the turn off pop since the RC time constant of the DC servo
is very slow. Please contact Tripath sales for additional information on the DC servo circuit.
Protection Circuits
The TA2024C is guarded against over-temperature and over-current conditions. When the
device goes into an over-temperature or over-current state, the FAULT pin goes to a logic HIGH
state indicating a fault condition. When this occurs, the amplifier is muted, all outputs are TRI-
STATED, and will float to 1/2 of VDD.
Over-temperature Protection
An over-temperature fault occurs if the junction temperature of the part exceeds approximately
155°C. The thermal hysteresis of the part is approximately 45°C, therefore the fault will
automatically clear when the junction temperature drops below 110°C.
13
TA2024C –KL/1.0/01.06