3) Switching capacity and expected life
(1) Electrical (at 20 times/min.)
Load
Resistive (cos ϕ = 1)
AC
Inductive (cos ϕ 0.4)
Voltage
125V AC
250V AC
125V AC
250V AC
10A
10A
5A
3A
1 Form C
7A
7A
3A
2.5A
5A
5A
2A
1.5A
7A
7A
3.5A
2A
2 Form C
5A
5A
2.5A
1.5A
3A
3A
1.5A
1A
7A
7A
3 Form C
3.5A
2A
5A
5A
5A
5A
2A
1A
4 Form C
3A
3A
1A
0.8A
2A
2A
0.5A
0.4A
4 Form C (twin)
3A
3A
1A
0.8A
(2) Mechanical (at 180 times/min.)
AC coil type: Min. 5×107; DC coil type: Min. 108
HC
DC
Resistive
Inductive
30V DC
30V DC
3A
1A
3A
0.6A
3A
0.4A
3A
0.4A
3A
Expected life
Min. 2×105
Min. 5×105
Min. 106
Min. 2×105
Min. 5×105
Min. 106
Min. 105
Min. 2×105
Min. 5×105
Min. 2×105
Min. 5×105
Min. 106
Min. 2×105
2. Amber sealed type
1) Coil data
Same coil data as HC relay standard type. Please refer to standard type information.
2) Specifications
Characteristics
Contact
Rating
Electrical characteristics
Expected life
Conditions
Item
Arrangement
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Temperature rise (coil) (at 60°C 140°F)
Electrical
Conditions for operation, transport and
storage*2
Ambient air pressure
Specifications
1 Form C
2 Form C
4 Form C
4 Form C (twin)
1 Form C
2 Form C
4 Form C
4 Form C
5A 250V AC
3A 250V AC
2A 250V AC
1A 250V AC
1,250VA
700VA
500VA
250VA
250VAC
250VAC
250VAC
250VAC
5A
3A
2A
1A
1mA 100mV DC
100µA 100mV DC
Max. 90°C 194°F (By resistive method, nominal voltage)
Min. 2×105 resistive load (at 20 times/min.)
Ambient temperature: –40°C to +60°C –40°F to +140°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
760mmHg±20% (1,013mb±20%)
Notes: Other specifications are same as standard types.
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3) Switching capacity and expected life
(1) Electrical (at 20 times/min.)
Load
Voltage
AC
Resistive (cos ϕ = 1)
Inductive (cos ϕ 0.4)
125V AC
250V AC
125V AC
250V AC
HC1E
5A
5A
HC2E
3A
3A
HC4E
2A
2A
HC4ED (4 Form C twin)
1A
1A
DC
Resistive
Inductive
30V DC
30V DC
3A
1A
2A
0.7A
2A
0.6A
Expected life
Min. 2×105
Min. 2×105
Min. 2×105
Min. 2×105
(2) Mechanical (at 180 times/min.)
AC coil type: Min. 5×107; DC coil type: Min. 108