SLx 24C04
The timing conventions for read and write operations are described in figures 5 and 6.
Command Byte (CSW)
Data Transfer to EEPROM
SCL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
SDA
1 0 1 0 X X A8 0
A7 A6 A5 A4 A3 A2 A1 A0 ACK
START from Master
Acknowledge from EEPROM
Figure 5
Timing of the Command Byte CSW
Acknowledge from EEPROM
IED02256
Command Byte (CSR)
Data Transfer from EEPROM
SCL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
SDA
1 0 1 0 X X X 1 ACK
START from Master
Acknowledge from EEPROM
Figure 6
Timing of the Command Byte CSR
ACK
Acknowledge from Master
IED02185