datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

NB100ELT23L View Datasheet(PDF) - ON Semiconductor

Part Name
Description
View to exact match
NB100ELT23L Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
NB100ELT23L
Table 3. MAXIMUM RATINGS
Symbol
Parameter
Condition 1
Condition 2
Rating
Unit
VCC
Power Supply
VI
Input Voltage
Iout
Output Current
GND = 0 V
GND = 0 V
Continuous
Surge
VI  VCC
3.8
V
3.8
V
50
mA
100
mA
TA
Operating Temperature Range
Tstg
Storage Temperature Range
qJA
Thermal Resistance (Junction−to−Ambient) 0 lfpm
500 lfpm
SO−8
SO−8
−40 to +85
−65 to +150
190
130
°C
°C
°C/W
°C/W
qJC
Thermal Resistance (Junction−to−Case) Standard Board
SO−8
qJA
Thermal Resistance (Junction−to−Ambient) 0 lfpm
500 lfpm
TSSOP−8
TSSOP−8
41 to 44
185
140
°C/W
°C/W
°C/W
qJC
Thermal Resistance (Junction−to−Case) Standard Board
TSSOP−8
qJA
Thermal Resistance (Junction−to−Ambient) 0 lfpm
500 lfpm
DFN8
DFN8
41 to 44
129
84
°C/W
°C/W
°C/W
Tsol
Wave Solder
Pb <2 to 3 sec @ 248°C
Pb−Free <2 to 3 sec @ 260°C
265
°C
265
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 4. PECL DC CHARACTERISTICS VCC = 3.3 V, GND = 0 V (Note 2)
−40°C
25°C
85°C
Symbol
ICCH
ICCL
VIH
VIL
VIHCMR
Characteristic
Power Supply Current (Outputs set to HIGH)
Power Supply Current (Outputs set to LOW)
Input HIGH Voltage
Input LOW Voltage
Input HIGH Voltage Common Mode Range
(Note 3)
Min Typ Max Min Typ Max Min Typ Max Unit
10 14 20 10 15 20 10 15 20 mA
15 19 25 15 19 25 15 20 25 mA
2075
2420 2075
2420 2075
2420 mV
1355
1675 1355
1675 1355
1675 mV
1.2
3.3 1.2
3.3 1.2
3.3 V
IIH
Input HIGH Current
IIL
Input LOW Current
−150
150
−150
150
−150
150 mA
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. All values vary 1:1 with VCC.
3. VIHCMR minimum varies 1:1 with VEE, VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the
differential input signal.
http://onsemi.com
3
 

Share Link: 