MSA SERIES
5 WATT
DC/DC CONVERTERS
ABSOLUTE MAXIMUM RATINGS
Input Voltage
• 16 to 40 V
Output Power
• 5 watts
Lead Soldering Temperature (10 sec per lead)
• 300°C
Storage Temperature Range (Case)
• –65°C to +135°C
INHIBIT
Inhibit TTL Open Collector
• Logic low (output disabled)
Logic low voltage 0.8 V max
Inhibit pin current 4 mA max
• Referenced to input common
• Logic high (output enabled)
Open collector
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
• 16 to 40 VDC continuous
• 50 V for up to 50 msec transient
Case Operating Temperature (Tc)
• –55°C to +125°C full power
• –55°C to +135°C absolute
Derating Output Power/Current (Tc)
• Linearly from 100% at 125°C to 0% at 135°C
TYPICAL CHARACTERISTICS
Output Voltage Temperature Coefficient
• 100 ppm/°C typical
Input to Output Capacitance
• 50 pF typical
Isolation
• 100 megohm minimum at 500 V
Audio Rejection
• 50 dB typical
Conversion Frequency
• 550 kHz typical (400 kHz 60 V model)
450 kHz min, 600 kHz max
350 kHz min, 450 kHz max 60 V model
Inhibit Pin Voltage (unit enabled)
• 9 to 11 V
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
SINGLE OUTPUT MODELS
PARAMETER
CONDITIONS
OUTPUT VOLTAGE Tc = –55°C TO +125°C
OUTPUT CURRENT
Tc = –55°C TO +125°C VIN = 16 TO 40 VDC
OUTPUT POWER
VIN = 16 TO 40 VDC
Tc = –55°C TO +125°C
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
Tc = –55°C TO +125°C
INPUT RIPPLE
CURRENT
EFFICIENCY
LOAD FAULT3, 4
SHORT CIRCUIT
STEP LOAD
RESPONSE4, 5
10 kHz - 2 MHz
VIN = 16 TO 40 VDC
Tc = –55°C TO +125°C
NO LOAD TO FULL
Tc = –55°C TO +125°C
Tc = –55°C TO +125°C
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
FULL LOAD
INHIBITED
10 kHz - 10 MHz
Tc = –55°C TO +125°C
POWER DISSIPATION
RECOVERY
50% - 100% - 50%
TRANSIENT
RECOVERY
STEP LINE
RESPONSE4, 5
TRANSIENT
16 TO 40 VIN
40 TO 16 VIN
RECOVERY
16 TO 40 VIN
40 TO 16 VIN
START-UP
DELAY
OVERSHOOT
MSA2805S
MSA285R2S
MSA2812S
MSA2815S
MIN TYP MAX MIN TYP MAX MIN TYP MAX MIN TYP MAX
4.95 5.00 5.05 5.15 5.20 5.25 11.88 12.00 12.12 14.85 15.00 15.15
0 — 1000 0 — 962 0 — 417 0 — 333
—— 5 — — 5 —— 5 — — 5
— 125 350 — 110 335 —
— 10 502 — 10 50 —
50 200 —
10 50 —
50 170
10 50
— 10 50 — 10 50 — 10 50 — 10 50
16 28 40 16 28 40 16 28 40 16 28 40
0 — 50 0 — 50 0 — 50 0 — 50
— 27 40 — 28 40 — 29 42 — 31 44
— 250 — — 250 — — 235 — — 235 —
—3
5 — 3 5 —3
5—3 5
— 25 100 — 25 100 — 25 100 — 25 100
— 30 150 — 30 150 — 30 150 — 30 150
66 71 — 66 71 — 70 76 — 71 76 —
— 1.5 2.0 — 1.5 2.0 — 1.2 1.9 — 1.2 1.8
— 12.5 25 — 1.5 25 — 1 10 — 1 10
— 100 250 — 100 250 — 150 375 — 200 500
— 100 250 — 100 250 — 200 500 — 200 500
— 50 150 — 50 150 — 80 200 — 50 125
— 50 150 — 50 150 — 100 250 — 50 125
— 100 250 — 100 250 — 250 625 — 250 625
— 200 500 — 200 500 — 250 625 — 250 625
— 10 25 — 10 25 — 3 10 — 3 10
— 0 50 — 0 50 — 0 120 — 0 150
MSA2860S1
MIN TYP MAX
59.1 60.00 60.9
0 — 20
— — 1.2
— — 300
— — 300
— — 300
16 28 40
0 — 50
— — 30
— 72 —
—35
— — 90
— ——
70 75 —
— ——
— ——
— ——
— ——
— ——
— ——
— ——
— ——
— ——
— ——
UNITS
VDC
mA
W
mV p-p
mV
mV
VDC
V
mA
mA p-p
%
W
ms
mV pk
µs
mV pk
µs
ms
mV pk
Notes
1. MSA2860S specifications are at 25°Tc only, contact your Interpoint
representative for more information on over temperature specs.
2. Line regulation for /ES and non /ES 2805S models at 16 to 17 VIN and 110
°C to 125°C (case) is 5% (max).
3. Indefinite short circuit protection not guaranteed above 125°C (case).
4. Recovery time is measured from application of the transient to point at which
VOUT is within 1% of VOUT at final value.
5. Transition time >10µs.