MSA-2743 Absolute Maximum Ratings[1]
Symbol Parameter
Units
Id
Pdiss
Pin max.
TJmax
TSTG
θjc
Device Current
Total Power Dissipation[2]
RF Input Power
Junction Temperature
Storage Temperature
Thermal Resistance [3]
mA
mW
dBm
°C
°C
°C/W
Absolute Maximum
80
330
20
150
-65 to 150
115
Notes:
1. Operation of this device above any one of
these parameters may cause permanent
damage.
2. Ground lead temperature is 25°C. Derate
8.7 mW/°C for TL > 112°C.
3. Thermal resistance measured using 150°C
Liquid Crystal Measurement method.
Electrical Specifications
TA = +25°C, Id = 50 mA, ZO = 50, RF parameters measured in a test circuit for a typical device
Symbol
Parameter and Test Condition
Frequency
Units
Min.
Typ.[1] Max. σ
Vd
Device Voltage, Id =50 mA
GP
Power Gain (|S21|2)
900 MHz
2 GHz
V
3.5
3.9
4.3
0.04
dB
16
0.18
14
15.5
17
0.17
GP
F3dB
VSWRin
VSWRout
NF
Gain Flatness
3 dB Bandwidth
Input Voltage Standing Wave Ratio
Output Voltage Standing Wave Ratio
50Noise Figure
0.1 to 2 GHz
dB
GHz
0.1 to 6 GHz
0.1 to 6 GHz
900 MHz
dB
2 GHz
±0.29
6.2
1.4:1
1.2:1
3.9
0.19
4.1
0.16
P1dB
Output Power at 1 dB Gain Compression
900 MHz
dBm
16.1
0.05
2 GHz
15
0.08
OIP3
Output Third Order Intercept Point
900 MHz
dBm
31
0.08
2 GHz
28
0.17
DV/dT
Device Voltage Temperature Coefficient
mV/°C
-4.4
Notes:
1. Typical value determined from a sample size of 500 parts from 6 wafers.
2. Standard deviation is based on 500 samples taken from 6 different wafers. Future wafers allocated to this product may have typical values
anywhere between the minimum and maximum specification limits.
Input
50 Ohm
Transmission Line
(0.5 dB loss)
50 Ohm
Output
DUT
Transmission Line
Including Bias T
(1.05 dB loss)
Block diagram of 2 GHz production test board used for gain measurements. Circuit losses have been de-embedded from actual measurements.