datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

MPS-30-27 View Datasheet(PDF) - Total Power International

Part Name
Description
View to exact match
MPS-30-27
TOTAL-POWER
Total Power International TOTAL-POWER
MPS-30-27 Datasheet PDF : 2 Pages
1 2
30W Single Output for Medical Type
MPS-30 series
Features :
Universal AC input / Full range
Low leakage current 0.3mA
Protections:Short circuit/Over load/Over voltage/Over temperature
Fixed switching frequency at 100KHz
Low cost
High reliability
3 years warranty
SPECIFICATION
MODEL
MPS-30-5
MPS-30-12
MPS-30-15
MPS-30-24
MPS-30-27
MPS-30-48
DC VOLTAGE
5V
RATED CURRENT
5A
12V
15V
2.5A
2A
24V
27V
48V
1.2A
1.1A
0.6A
CURRENT RANGE
RATED POWER
0 ~ 5A
25W
0 ~ 2.5A
30W
0 ~ 2A
30W
0 ~ 1.2A
28.8W
0 ~ 1.1A
29.7W
0 ~ 0.6A
28.8W
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
LINE REGULATION
1.0%
1.0%
LOAD REGULATION
2.0%
1.0%
SETUP, RISE, HOLD TIME 500ms, 30ms, 50ms/230VAC
150mVp-p
240mVp-p
3.0%
3.0%
0.5%
0.5%
1.0%
1.0%
500ms, 30ms, 10ms/115VAC at full load
240mVp-p
3.0%
0.5%
1.0%
240mVp-p
2.0%
0.5%
1.0%
VOLTAGE RANGE
88 ~ 264VAC auto switch 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY(Typ.)
72%
75%
76%
77%
78%
78%
AC CURRENT
0.8A/115VAC 0.5A/230VAC
INRUSH CURRENT(max.) COLD START 35A/230VAC
LEAKAGE CURRENT
<0.3mA / 264VAC
OVER LOAD
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
5.5 ~ 6.75V
13.2 ~ 16.2V
16.5 ~ 20.25V
26.4 ~ 32.4V
29.7 ~ 36.45V
Protection type : Shut down o/p voltage, re-power on to recover
Tj 135 typically (U1) Detect on main control IC
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +50 (Refer to output load derating curve)
52.8 ~ 64.8V
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL2601-1, TUV EN60601-1, IEC601-1 Approved
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:SHORT
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG:100M Ohms/500VDC
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2 Medical level, criteria A
MTBF
547Khrs min. MIL-HDBK-217F (25 )
DIMENSION
101.6*65.8*23.5mm (L*W*H)
PACKING
0.16Kg; 90pcs/15.8Kg/1.02CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
 

Share Link: 