datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

MC33880DW View Datasheet(PDF) - Motorola => Freescale

Part Name
Description
View to exact match
MC33880DW Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Freescale Semiconductor, Inc.
STATIC ELECTRICAL CHARACTERISTICS
Characteristics noted under conditions of 4.75 V VDD 5.25 V, 9.0 V VPWR 16 V, -40°C TC 125°C unless otherwise noted.
Typical values, where applicable, reflect the parameter’s approximate average value with VPWR = 13 V, TA = 25°C.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER INPUT
Supply Voltage Range
Fully Operational
VPWR(FO)
V
5.5
24.5
Supply Current
Sleep State Supply Current (VDD and EN = 0 V, VPWR = 16 V)
Temperature = -40°C to 95°C
Temperature = 95°C to 125°C
IPWR(ON)
IPWR(SS)
8.0
14
mA
µA
2.0
5.0
5.0
20
Overvoltage Shutdown
Overvoltage Shutdown Hysteresis
Logic Supply Voltage
Logic Supply Current
Logic Supply Undervoltage Lockout Threshold
Logic Supply Undervoltage Hysteresis
VOV
25
27
30
V
VOV(HYS)
0.15
0.8
2.5
V
VDD
4.75
5.25
V
IDD
0.5
2.6
4.0
mA
VDD(UNVOL)
3.9
4.3
4.7
V
VDD(UNVOL-HYS)
100
150
300
mV
POWER OUTPUT
Drain-to-Source ON Resistance (VPWR = 16 V)
IOUT = 0.25 A, TJ = 125°C
IOUT = 0.25 A, TJ = 25°C
IOUT = 0.25 A, TJ = -40°C
RDS(ON)
0.75
1.1
0.55
0.85
0.45
0.80
Output Self-Limiting Current High-Side and Low-Side Configurations
IOUT(LIM)
A
VPWR = 16 V
0.8
1.4
2.0
Output Fault Detect Threshold (Note 9), (Note 10)
Outputs Programmed OFF
VOUTth(F)
1.0
V
3.0
Output Off Open Load Detect Current (Note 9)
Outputs Programmed OFF
IOCO
mA
0.30
0.55
1.0
Output Clamp Voltage Low-Side Drive
ID = 10 mA
VOC(LSD)
V
40
45
55
Output Clamp Voltage High-Side Drive
IS = -30 mA
VOC(HSD)
V
-15
-20
-25
Output Leakage Current High-Side and Low-Side Configuration
VDD = 0 V, VDS = 16 V
IOUT(LKG)
µA
1.0
7.0
Overtemperature Shutdown (Note 10)
Overtemperature Shutdown Hysteresis (Note 10)
TLIM
155
TLIM(HYST)
5.0
10
185
°C
15
°C
Notes
9. Output Fault Detect Thresholds with outputs programmed OFF. Output fault detect threshold are the same for output open and shorts.
10. This parameter is guaranteed by design but is not production tested.
33880
8
For More Information OMnOTTOhRiOsLAPrAoNdAuLOcGt,INTEGRATED CIRCUIT DEVICE DATA
Go to: www.freescale.com
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]