MC-4532DA727
DC Characteristics (Recommended Operating Conditions unless otherwise noted)
Parameter
Symbol
Test condition
Grade MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1
/CAS latency = 2 -A75
2,200 mA 1
tRC tRC (MIN.), IO = 0 mA
/CAS latency = 3 -A75
2,290
Precharge standby current in ICC2P CKE VIL (MAX.), tCK = 15 ns
268 mA
power down mode
ICC2PS CKE VIL (MAX.), tCK =
98
Precharge standby current in
non power down mode
ICC2N
CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
610 mA
ICC2NS CKE VIH (MIN.), tCK = , Input signals are stable.
224
Active standby current in
ICC3P CKE VIL (MAX.), tCK = 15 ns
340 mA
power down mode
ICC3PS CKE VIL (MAX.), tCK =
152
Active standby current in
non power down mode
ICC3N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
790 mA
ICC3NS CKE VIH (MIN.), tCK = , Input signals are stable.
440
Operating current
ICC4 tCK tCK (MIN.), IO = 0 mA
/CAS latency = 2 -A75
2,290 mA 2
(Burst mode)
/CAS latency = 3 -A75
2,920
CBR (Auto) Refresh current
ICC5
tRC tRC (MIN.)
/CAS latency = 2 -A75
4,540 mA 3
/CAS latency = 3 -A75
4,720
Self refresh current
ICC6 CKE 0.2 V
286 mA
Input leakage current
II (L) VI = 0 to 3.6 V, All other pins not under test = 0 V
–20 +20 µA
Output leakage current
IO (L) DOUT is disabled, VO = 0 to 3.6 V
–1.5 +1.5 µA
High level output voltage
VOH IO = –4.0 mA
2.4
V
Low level output voltage
VOL IO = +4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet E0073N20
 

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]