MC-4516DA726
AC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Test Conditions
Parameter
AC high level input voltage / low level input voltage
Input timing measurement reference level
Transition time (Input rise and fall time)
EOutput timing measurement reference level
O 2.4V
CLK 1.4 V
L 0.4 V
Value
2.4 / 0.4
1.4
1
1.4
tCK
tCH
tCL
tSETUP tHOLD
Unit
V
V
ns
V
Input
2.4 V
1.4 V
0.4 V
Product Output
tAC
tOH
Data Sheet E0074N10