datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

LA55-P View Datasheet(PDF) - LEM Industrial

Part Name
Description
View to exact match
LA55-P
LEM
LEM Industrial LEM
LA55-P Datasheet PDF : 2 Pages
1 2
Current Transducer LA 55-P
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 50 A
Electrical data
IPN
Primary nominal r.m.s. current
I
Primary current, measuring range
P
RM Measuring resistance @
50
A
0 .. ± 70
A
TA = 70°C TA = 85°C
RR RR
M min M max M min M max
with ± 12 V
with ± 15 V
@ ± 50 A
max
@ ± 70 A max
@ ± 50 A
max
@ ± 70 A max
10 100 60 95
10 50 601) 601)
50 160 135 155
50 90 13 52) 1352)
ISN
Secondary nominal r.m.s. current
K N Conversion ratio
VC Supply voltage (± 5 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
50
mA
1 : 1000
± 12 .. 15
V
10 (@ ±15 V) + IS mA
2.5
kV
Accuracy - Dynamic performance data
X
Accuracy @ I , T = 25°C
@ ± 15 V (± 5 %) ± 0.65
%
PN A
@ ± 12 .. 15 V (± 5 %) ± 0.90
%
εL
Linearity
< 0.15
%
Typ Max
I
Offset current @ I = 0, T = 25°C
O
P
A
± 0.2 mA
IOM
Residual current 3) @ IP = 0, after an overload of 3 x IPN
± 0.3 mA
I
Thermal drift of I
OT
O
0°C .. + 70°C ± 0.1 ± 0.5 mA
- 25°C .. + 85°C ± 0.1 ± 0.6 mA
tra
t
r
di/dt
f
Reaction time @ 10 % of IP max
Response time @ 90 % of I
P max
di/dt accurately followed
Frequency bandwidth (- 1 dB)
< 500
<1
> 200
DC .. 200
ns
µs
A/µ s
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
R S Secondary coil resistance @
m
Mass
Standards 4)
- 25 .. + 85
°C
- 40 .. + 90
°C
TA = 70°C 80
TA = 85°C 85
18
g
EN 50178
Features
Closed loop (compensated) current
transducer using the Hall effect
Printed circuit board mounting
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Notes : 1) Measuring range limited to ± 60 A
max
2) Measuring range limited to ± 55 A
max
3) Result of the coercive field of the magnetic circuit
4) A list of corresponding tests is available
980706/8
LEM Components
w w w .lem.com
 

Share Link: 